Tripp Lite PDU3VSR6L2130 Owner's Manual for SNMPWEBCARD 9332CE - Page 55

Schedules

Page 55 highlights

4. Telnet/SSH Console continued 4.2 System Configuration continued 4.2.2.2 Schedules To have access to the schedules menu, the user must have at least Read access to the SCHEDULES facility. Because controls and loads can be scheduled, the user should have at least read access to the DEVICE CONTROLS and DEVICE LOADS facilities as well. Once a schedule has been created, it cannot be modified. To change a schedule, the original schedule has to be removed and a new schedule created. -------- Schedules Menu # Pending Action Next Fire Time Frequency 1 Initiate Self Test 2011-12-08 16:10:00-06:00 Daily 2 Initiate Self Test 2011-12-07 16:12:00-06:00 Once 3 Initiate Self Test 2011-12-07 16:13:00-06:00 Weekly 4 Initiate Self Test 2012-01-15 16:15:00-06:00 Yearly 5 Initiate Self Test 2011-12-15 16:17:00-06:00 Monthly 6 Initiate Self Test 2012-02-01 16:18:00-06:00 Monthly 7 Initiate Self Test 2012-11-24 16:19:00-06:00 Yearly #- View Schedule 0- Add New Schedule X/M- Return to Main Menu Refresh Menu Execute Once Schedule -------- Schedule Detail Menu Pending Action Device Id Frequency Next Fire Time : Initiate Self Test : 1 : Once : 2011-12-07 16:12:00-06:00 D- Delete Schedule X- Schedules Menu M- Return to Main Menu Refresh Menu Execute Daily Schedule -------- Schedule Detail Menu Pending Action Device Id Frequency Interval Next Fire Time Until : Initiate Self Test : 1 : Daily : Every Day : 2011-12-08 16:10:00-06:00 : Forever D- Delete Schedule X- Schedules Menu M- Return to Main Menu Refresh Menu 55

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

55
4.2 System Configuration
continued
4.2.2.2 Schedules
To have access to the schedules menu, the user must have at least Read access to the SCHEDULES facility.
Because controls and loads can be
scheduled, the user should have at least read access to the DEVICE CONTROLS and DEVICE LOADS facilities as well.
Once a schedule has been created, it cannot be modified.
To change a schedule, the original schedule has to be removed and a new schedule
created.
-------- Schedules Menu --------------------------------------------------------
--------------------------------------------------------------------------------
# Pending Action
Next Fire Time
Frequency
--------------------------------------------------------------------------------
1 Initiate Self Test
2011-12-08 16:10:00-06:00
Daily
2 Initiate Self Test
2011-12-07 16:12:00-06:00
Once
3 Initiate Self Test
2011-12-07 16:13:00-06:00
Weekly
4 Initiate Self Test
2012-01-15 16:15:00-06:00
Yearly
5 Initiate Self Test
2011-12-15 16:17:00-06:00
Monthly
6 Initiate Self Test
2012-02-01 16:18:00-06:00
Monthly
7 Initiate Self Test
2012-11-24 16:19:00-06:00
Yearly
#- View Schedule
0- Add New Schedule
X/M- Return to Main Menu
<ENTER> Refresh Menu
Execute Once Schedule
-------- Schedule Detail Menu --------------------------------------------------
Pending Action
: Initiate Self Test
Device Id
: 1
Frequency
: Once
Next Fire Time
: 2011-12-07 16:12:00-06:00
D- Delete Schedule
X- Schedules Menu
M- Return to Main Menu
<ENTER> Refresh Menu
Execute Daily Schedule
-------- Schedule Detail Menu --------------------------------------------------
Pending Action
: Initiate Self Test
Device Id
: 1
Frequency
: Daily
Interval
: Every Day
Next Fire Time
: 2011-12-08 16:10:00-06:00
Until
: Forever
D- Delete Schedule
X- Schedules Menu
M- Return to Main Menu
<ENTER> Refresh Menu
4. Telnet/SSH Console