HP D5970A HP Netserver LXr 8000 to LXr 8500 Upgrade Guide
HP D5970A - NetServer - LCII Manual
View all HP D5970A manuals
Add to My Manuals
Save this manual to your list of manuals |
HP D5970A manual content summary:
- HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 1
HP NetServer LXr 8000 to LXr 8500 Upgrade Guide HP Part Number 5967-6669 Printed in September 1999 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 2
-Packard shall not be liable for errors contained herein or for incidental or the use or reliability of its software on equipment that is not furnished guide is for the person who installs, administers, and troubleshoots LAN servers. Hewlett-Packard Company assumes you are qualified in the servicing - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 3
1 A Brand-new Server 1 Verify NOS Versions Supported by the LXr 8500 1 Determine Which Accessories You Need 2 Memory ...2 Processors 3 PCI Boards 3 Returning LXr 8000 Components to HP 3 Call for Installation 4 Overview of the Upgrade 5 Purpose of This Guide 6 Related Documentation - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 4
Board and Center Support 42 Install the NetServer 64 Common Installation Problems 65 The NetServer Will Not Power On 65 The NetServer Power is On, but There is No Display on the Monitor........ 66 The NetServer Power is On, but System Information Does Not Match Hardware 66 Start the HP NetServer - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 5
the Basic System Test 79 Create Support Ticket 80 Use the Error Code Viewer to Review Corrective Actions 80 Use HP DiagTools to Burn in the NetServer 81 Exit HP DiagTools and Take Corrective Action if Necessary 81 Reinstall Your NOS 81 Prepare Your Boot Drive 82 Install Your NOS and Configure - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 6
- HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 7
to an LXr 8500. Be sure to identify your NetServer as having been upgraded to an LXr 8500 before a service representative comes to your site. Because this upgrade provides the equivalent of a brand-new server, be sure you follow the instructions in this chapter to verify NOS versions and determine - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 8
: l DIMM sizes can be mixed per board, and can be placed in any DIMM socket. There are no requirements to load the sockets in any specific sequence. • For up to eight DIMMs, use one memory board. • For more than eight DIMMs, a second memory board must be installed to maintain compliance with - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 9
NOTE Consult your NOS documentation to determine the maximum amount of memory supported by your NOS. For example, Microsoft Windows NT 4.0 and Novell processors for a total of eight processors. CAUTION When the HP NetServer LXr 8500 is configured with multiple processors, all the processors must - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 10
Primary Service Office. In other locations, you will be charged for travel. Please call HP at one of the following numbers to schedule this service. Country 6087400 01-4828555 (91) 631 19 12 08-444 25 57 1-800-500-1176 Fax (0222) 25000-500 02 778 3079 (02) 61307 289 45991665 01 69 82 66 33 02102 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 11
Terminators I/O baseboard and tray Remote control card I/O riser board Power supplies Memory board DIMMs Center support Midplane board Peripheral bay Hard disk drives Tape drive CD-ROM drive Chassis Top cover Embedded I/O cover Front bezel Bezel hinge Cable management arm Use existing components - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 12
you need to perform to convert the HP NetServer LXr 8000 to the HP NetServer LXr 8500. This guide includes the following topics: • Chapter . • Chapter 6, "Preliminary Hardware Verification" instructs you to turn on power to the NetServer, perform initial hardware verification, and update your - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 13
HP NetServer LXr 8500: • The HP NetServer LXr 8500 Installation Guide • HP NetServer LXr 8500 Technical Reference Card • HP NetServer cooling airflow over some components, such as hard disk drives and processor modules. Continuous operation of the NetServer without all covers in place will increase - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 14
- HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 15
accessory you need the following tools: • An anti-static service kit (3M™ 8501/8502/8503 or equivalent). This kit includes HP NetServer LXr 8500 Installation Guide and your rack documentation for further details. Back Up Your Data Before you start the upgrade, you must back up all hard disk drives - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 16
from the "More NetServer Utilities" option. If there are problems with the system, troubleshoot these before continuing with the upgrade. You might want to save the Event Log file before you proceed. Refer to the HP NetServer LXr 8000 Installation Guide and the HP NetServer Online Documentation CD - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 17
anti-static container until you are ready to install them. • Use an anti-static wrist strap and a grounding mat. Read and follow the instructions included with the wrist strap and mat. • Before you remove a component from its anti-static container, touch a grounded, unpainted metal surface on the - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 18
with the documentation set: l HP NetServer LXr 8000 to LXr 8500 Upgrade Guide (this guide) l Complete documentation for the HP NetServer LXr 8500, including the Installation Guide and Rack Assembly and Cabling Reference Guide l HP NetServer Navigator CD-ROM l HP NetServer Online Documentation CD-ROM - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 19
Chapter 2 Processor Box Preparing for the Upgrade Processor Tray with 7 Terminators I/O Box Figure 2-2. Contents of Processor Box Figure 2-3. Contents of I/O Box 13 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 20
Chapter 2 Power Supply Box Preparing for the Upgrade Figure 2-4. Contents of Power Supply Box Memory Board Box Figure 2-5. Contents of Memory Box 14 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 21
Chapter 2 Midplane Box Preparing for the Upgrade Bezel Box Figure 2-6. Contents of Midplane Box Bezel Hinge Front Bezel NOTE Tie-down Kit Figure 2-7. Contents of Bezel Box The tie-down kit is not necessary for the upgrade and is used only to prepare a NetServer for shipment in a rack. 15 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 22
Chapter 2 Top Cover Box Preparing for the Upgrade Top Cover Figure 2-8. Contents of Top Cover Box Sheet Metal Box Embedded I/O Cover Center Support Figure 2-9. Contents of Sheet Metal Box 16 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 23
Chapter 2 Cable Management Arm Box Preparing for the Upgrade Cable Management Arm Figure 2-10. Contents of Cable Management Arm Box 17 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 24
- HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 25
Remove midplane board and center support. l Apply gaskets to chassis. CAUTION Do not proceed until you have followed the instructions in Chapter 2 to back all users, and shut down the operating system. 2. Turn off the NetServer and monitor. 3. If necessary, label all external cables before you - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 26
upgrade without removing the NetServer from the rack. However, depending on where the NetServer is located in the rack, you might find it easier to remove it from the rack before proceeding. Refer to the HP NetServer LXr 8000 Installation Guide for help in removing the NetServer from the rack. 20 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 27
chassis. (See Figure 3-2.) Place the front bezel on the table of items that will not be reused in the NetServer LXr 8500. 9. Detach the front bezel hinge from the chassis. Insert the Torx® driver through the hinge to remove all three screws. (See Figure 3-2.) Place the front bezel hinge on the table - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 28
the top cover back, and lifting it up. (See Figure 3-3.) Place this cover on the table of items that will not be reused in the NetServer LXr 8500. 22 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 29
Chapter 3 Remove Memory Boards Disassembling the LXr 8000 12. Lift LCD handle. 13. Loosen three thumbscrews and remove memory bay cover. Figure 3-4. Remove Memory Bay Cover 12. Lift the LCD handle. 13. Unscrew the three thumbscrews and remove the memory bay cover. (See Figure 3-4.) The memory bay - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 30
DIMMs from the LXr 8000 into the memory boards for the LXr 8500. Do not use the memory boards from the LXr 8000 in the NetServer LXr 8500. 24 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 31
the fan cover toward you, lifting the front of the cover, and then disengaging the tabs. (See Figure 3-6.) This item will be reused in the NetServer LXr 8500. 16. Remove all six fans by pulling them straight up. All fans will be reused in the - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 32
the fan cage to the chassis. b. Tilt the fan cage forward and remove. Be careful of the light pipes at the bottom of the fan cage. The fan cage will be reused in the NetServer LXr 8500. 18. Remove the air baffle from the fan cage by unscrewing the two screws. Place - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 33
screws attaching the processor tray to the chassis. Looking at the front of the NetServer, there are two screws on the right and one on the left. (See Figure midplane board. 21. Remove the processor tray. You may have to pull fairly hard. Set the processor tray on the table with items that will not be - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 34
the embedded I/O cover from the I/O tray. (See Figure 3-9.) Place the I/O cover on the table with items that will not be reused in the NetServer LXr 8500. 23. Disconnect the three peripheral bay ribbon cables from the I/O baseboard. To help you reconnect these cables later, you should label each - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 35
three screws. Figure 3-10. Remove I/O Tray 25. Remove the three screws connecting the I/O tray to the chassis. (See Figure 3-10.) From the back of the NetServer, there are two screws on the right and one on the left. 26. Disengage the I/O tray from the midplane board by opening the latches. 27 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 36
Board and Center Support 28. Remove center support. Figure 3-11. Remove Center Support 28. Remove the center support. (See Figure 3-11.) There are three screws that connect the center support to the chassis. Place the center support with the items that will not be reused in the NetServer LXr 8500 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 37
Chapter 3 Disassembling the LXr 8000 29. Disconnect peripheral bay power connector. Figure 3-12. Disconnect Peripheral Bay Power Connector 29. Disconnect the peripheral bay power connector from the midplane board. (See Figure 3-12.) 31 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 38
midplane board away from the sheet metal and lift. Place the midplane board on the table of items that will not be reused in the NetServer LXr 8500. 32 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 39
Chapter 3 Disassembling the LXr 8000 Apply Gaskets to Chassis 32. Remove adhesive strip covering from 2 short folded foam gaskets and apply to bottom corners of chassis. 31. Remove 4 screws and slide out peripheral bay. 33. Reinsert the peripheral bay and secure all 4 screws. Figure 3-14. Remove - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 40
- HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 41
8500 This chapter describes how to put together the following NetServer LXr 8500 subassemblies: • processor tray l memory board Prepare However, this upgrade kit comes with two processor carrier boards and supports a maximum of eight processors. Additional processors can be purchased separately. - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 42
Chapter 4 Preparing to Assemble the LXr 8500 2. Place the processor tray for the LXr 8000 on a table next to the LXr 8500. NOTE Placing the two processor trays next to each other will reduce the chance of damaging a processor due to static electricity when you move the processor from the old - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 43
Chapter 4 Preparing to Assemble the LXr 8500 Remove just one processor from the LXr 8000, turn it 180 degrees, and insert it in the LXr 8500. (Later you will move the remaining processors.) LXr 8000 Processor Cage LXr 8500 Processor Cage Figure 4-2. Install One Processor in the LXr 8500 5. - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 44
15 13 11 9 7 5 3 1 16 14 12 10 8 6 4 2 400 MHz 15 13 11 9 7 5 3 1 16 14 12 10 8 6 4 2 450 MHz 15 13 11 9 7 5 3 1 16 14 12 10 8 6 4 2 500 MHz 15 13 11 9 7 5 3 1 16 14 12 10 8 6 4 2 Store unused jumpers like this. 15 13 11 9 7 5 3 1 16 14 12 10 8 6 4 2 550 MHz Dark bars indicate - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 45
Chapter 4 Preparing to Assemble the LXr 8500 Prepare the LXr 8500 Memory Board(s) Figure 4-5. Install DIMMs in LXr 8500 Memory Board 1. Install the 256-MB SDRAM DIMM that came with this upgrade kit on the LXr 8500 memory board. (See Figure 4-5.) CAUTION You cannot transfer the EDO DIMMs from - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 46
- HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 47
5 Assembling the LXr 8500 This chapter describes the following steps of assembling the NetServer LXr 8500. • Install the midplane board and center support. • Install the I/O baseboard and tray. • Check I/O configuration switches. • Install the I/O riser board and remote control card. • Install the - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 48
Chapter 5 Assembling the LXr 8500 Install the Midplane Board and Center Support 1b. Orient the midplane board so that: - the notches point down - the peripheral bay power connector faces the front of the NetServer 1c. Angle the midplane as you insert it, then fasten all four screws. Figure 5-1. - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 49
Chapter 5 Assembling the LXr 8500 Figure 5-2. Plug in the Peripheral Bay Power Cable 2. Plug the peripheral bay power cable into the midplane board. You will hear it click. (See Figure 5-2.) NOTE Do not route the peripheral bay power cable such that it rests against the power supply AC cable. - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 50
the midplane. 3c. Fasten three screws. Figure 5-3. Install Center Support 3. Locate the LXr 8500 center support and install it as follows (see Figure 5-3): a. Orient the center support so the plastic PCI board guides face the back of the NetServer where you will reinstall the I/O tray. b. Place the - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 51
Chapter 5 Assembling the LXr 8500 4. Use the cable sheath to cover the peripheral bay ribbon cables. Figure 5-4. Attach Cable Sheath to Peripheral Bay Ribbon Cables 4. Attach the new cable sheath to the peripheral bay ribbon cables. This cable sheath protects the cables from being pinched during - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 52
Chapter 5 Assembling the LXr 8500 Figure 5-5. Route Ribbon Cables 5. Route the peripheral bay ribbon cables through the midplane cable guide. Align the cable sheath with the offset edge of the chassis. (See Figure 5-5.) NOTE The peripheral bay ribbon cables must be close to the side - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 53
, and that you screw in all three of the I/O tray screws at this time. If this order of assembly is not followed, you might find problems with the interconnects and with the alignment of screws. 47 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 54
Chapter 5 Assembling the LXr 8500 7. Connect three peripheral bay ribbon cables to I/O baseboard. Figure 5-7. Connect Ribbon Cables 7. Connect the three peripheral bay ribbon cables to the I/O baseboard. Each cable has a different shape connector. (See Figure 5-7.) 48 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 55
Chapter 5 Assembling the LXr 8500 Check I/O Configuration Switches I/O Configuration Switches SCSI A SCSI B IDE (CD-ROM) Floppy Disk Drive J1F1 (use with cable for Remote Control card) PCI LED Cable 10 9 8 7 6 5 4 3 2 1 I/O Riser Slot Slots 9 & 10 Slots 7 & 8 +3.3 VDC +3.3 VDC 66/33 MHz - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 56
of the switches are set in the "Open" (or "Off") position, and normally do not have to be changed. See Figure 5-9. Rear of NetServer 1 Reserved 2 Recovery Boot Open 3 Reserved 4 Reserved 5 CMOS Clear 6 Password Clear Shaded rectangle 7 PCI Hot-Plug Switch Disable represents the 8 Reserved - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 57
Chapter 5 Assembling the LXr 8500 Install I/O Riser Board and Remote Control Card 9. Install the I/O Riser board in the I/O Riser slot of the I/O baseboard. 10. Secure the I/O Riser board with a screw. Figure 5-10. Install the I/O Riser Board 9. Install the I/O riser board in the embedded I/O - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 58
Chapter 5 Assembling the LXr 8500 11. Press the center of the PCI hold-down latch in Slot 2. Then swing it back out of the way. Figure 5-11. Open the PCI Hold-down Latch in Slot 2 11. Locate Slot 2 on the I/O baseboard (see Figure 5-8) and open the PCI hold-down latch. (See Figure 5-11.) 12. - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 59
Chapter 5 Assembling the LXr 8500 Install the Processor Tray 14a. Align processor tray and slide it in. 14b. Check that the peripheral bay ribbon cables are out of the way. 14c. Press processor tray levers into the vertical position. 14d. Secure all eleven screws. Figure 5-13. Install Processor - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 60
LCD handle up until it stops. b. Locate the memory board guides, and insert the board(s) with the component-side down. NOTE You must insert the memory boards into the board guides for them to engage correctly. If you are using only one memory - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 61
Chapter 5 Assembling the LXr 8500 17. Lower the LCD handle. 16. Install the memory bay cover. Figure 5-15. Install Memory Bay Cover 16. Install the memory bay cover, and fasten the three thumbscrews. (See Figure 5-15.) The copper flanges are on the bottom of the cover. 17. Lower the LCD handle. - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 62
front and one on each side). CAUTION Make sure you have removed the fan cage air baffle before you attempt to install the fan cage. Instructions for removing the air baffle appear in Figure 3-7. Be careful you don't break the light pipes on the bottom of the fan cage. 56 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 63
the connector on the bottom of the fan is located on the left side. The arrow on the fans point to the rear of the NetServer. 20. Install the fan cover. a. Set the fan cover tabs in place, pull the cover toward you, then push the cover back into place. b. Secure - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 64
one label just below the serial number on the chassis. b. Apply the second label to the pull-out card that can be read when the NetServer is installed in the rack. 58 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 65
5-19. Locate Gaskets 22. Locate the remaining gaskets shipped with other miscellaneous parts. Each gasket has an adhesive strip to secure it to the NetServer. (See Figure 5-19.) You should have: ◊ Three long folded-foam gaskets for the tops of the power supply bays ◊ Three medium-length folded-foam - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 66
Chapter 5 Assembling the LXr 8500 Open tabs of metal gaskets 24d. Center long gaskets on point to center of NetServer. top edge of each power supply bay. 24a. Place medium-length gasket about 1 inch (25mm) in from edge of chassis. 24b. Place "CAUTION" label behind - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 67
one metal gasket to each side of each power supply bay as follows: ∗ The open tab of each gasket points toward the center of the NetServer. ∗ For the two metal gaskets that must be secured to the sides of the chassis, place the two gasket holes over the two metal inserts - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 68
Chapter 5 Assembling the LXr 8500 25. Slide each power supply module into place and press each lever into the upright position. Figure 5-21. Install All Three Power Supply Modules 26. Reconnect the power, monitor, keyboard, and mouse cables. Once power is connected, but not turned on, the LCD will - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 69
to the rack. You will: l Check the hardware. l Power on the NetServer. l Resolve common installation problems. l Start the HP NetServer Navigator CD-ROM and update the BIOS and firmware. Hardware Checklist Before starting the NetServer, check your hardware. l The processor tray should be set up as - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 70
The green, power LEDs for all ten PCI slots at the rear of the NetServer should light up. There is one power LED for each PCI slot. NOTE If some of 9904022002 (**BIOS Version**) Build Time: XXXX 1X Pentium® III Xeon™ Processor 500 MHz (**Number and Speed of CPUs**) 000000640K System RAM - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 71
sure the system recognizes your hard drives and tape drive if you have one. Detected devices are listed on the monitor. Common Installation Problems For further information about any of these troubleshooting tips, see the HP NetServer LXr 8500 Installation Guide. The NetServer Will Not Power On Use - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 72
do not appear on the monitor or LCD, call your service representative. The NetServer Power is On, but System Information Does Not Match Hardware l If the memory does not match what is installed in the NetServer: a. Make sure you have installed HP-supported SDRAM DIMMs. b. Make sure you did not move - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 73
the instructions in "Run Setup Utility" in Chapter 8 to change the Processor Retest Option to Yes. c. Power on the NetServer again and check to see if the problem has been corrected. If not, turn off power, disconnect the AC power cord, and reseat the processor. Start the HP NetServer Navigator - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 74
6 Preliminary Hardware Verification 5. Follow the instructions on the screen to begin the update. When the BIOS update is complete, the NetServer restarts. 6. As the NetServer restarts, note any POST errors and refer to the HP NetServer LXr 8500 Installation Guide as necessary. 7. Once the BIOS - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 75
processors l Installing accessory boards on the I/O baseboard l Installing the top cover and bezel. NOTE If you removed the NetServer from the rack, see the HP NetServer LXr 8500 Installation Guide for instructions on reinstalling it in the rack. Add Remaining Processors CAUTION Be sure the - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 76
are dual mode and can be used in either 3.3V and 5V slots.) ◊ All slots support 32-bit and 64-bit PCI boards. ◊ Slots 7-10 are 66 MHz capable, but BIOS will search for the boot drive) is set by the board's slot location. See the HP NetServer LXr 8500 Installation Guide for more information. ◊ Where - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 77
keyed such that they can be placed in any slot. Refer to the HP NetServer LXr 8500 Installation Guide for more complete information on adding accessory boards. Install Accessory Boards in the to the individual slot, or if the slot has a problem, such as a cable is disconnected from the board. 71 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 78
accessory board. CAUTION Do not bend the accessory board to install it into the slot. If the PCI board is full-length, the PCI board guide at the rear of the PCI slot is used to hold the board in place. The PCI board - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 79
Chapter 7 Finishing the Assembly 5d. Close the PCI board guide latch after installing each full-length accessory board. Figure 7-3. PCI Board Guide Latch d. Close the PCI board guide latch after installing each full-length accessory board. (See Figure 7-3.) 6. For all unused PCI slots, make sure - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 80
Chapter 7 Finishing the Assembly 7. Install embedded I/O cover. Figure 7-4. Install the Embedded I/O Cover 7. Install the embedded I/O cover over the right side of the I/O tray. (See Figure 7-4.) 74 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 81
Chapter 7 Finishing the Assembly Install the Top Cover, Bezel, and Cables Figure 7-5. Replace Top Cover 8. Install the new top cover. This top cover has the new Technical Reference Label for the NetServer LXr 8500. (See Figure 7-5.) 75 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 82
11. Install the new plastic front panel bezel. 12. Attach the cable management arm if you have an HP System rack. See the HP NetServer LXr 8500 Installation Guide for instructions. 13. Slide the NetServer back into the rack and secure it to the rack. 14. Reconnect the power, monitor, keyboard, mouse - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 83
changes as necessary. NOTE Do not assign IRQs manually. The NetServer LXr 8500 uses APIC mode to assign non-conflicting IRQs automatically. Any IRQs you assign manually will be overridden. See the HP NetServer LXr 8500 Installation Guide for more information. e. Save your changes and exit - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 84
Reinstalling Your NOS Run the HP DiagTools Utility HP DiagTools is an offline diagnostic program that validates hardware and helps distinguish hardware problems from software or configuration issues. It is recommended that you run DiagTools now and test your NetServer LXr 8500 before you reinstall - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 85
instructions on the screen to begin Configuration Detection. HP DiagTools scans the NetServer HP DiagTools cannot test components it has not detected. NOTE HP DiagTools does not list the CD-ROM drive on the Configuration Detection screen. HP instructions in the section "Create a Support Ticket." 79 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 86
your tests failed, view or print your results by following the instructions in the section "Create a Support Ticket" then look up the error codes by following the instructions in the section "Error Code Viewer." Create Support Ticket The Support Ticket lets you save the results to a file so you can - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 87
name of the error is displayed along with possible corrective actions. 7. Press Esc to return to the Advanced System Tests menu. Use HP DiagTools to Burn in the NetServer You can burn in the NetServer using DiagTools' repetitive tests. For complete information, see the instructions on batch testing - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 88
all partitions on your boot drive. 2. Repartition the drive. NOTE If you have any problems with your boot drive during NOS installation, it is recommended that you reformat the hard drive using the Symbios utility. To start the Symbios utility, 1. Restart your NetServer and press when - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 89
4. Exit HP NetRAID Express Tools. The NetServer restarts. Install Your NOS and Configure the NetServer 1. Insert the HP NetServer Navigator CD-ROM and restart the NetServer. 2. Open the Readme File from the HP NetServer Navigator menu to find up-to-date configuration information. For instructions on - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 90
- HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 91
NetServer Warranty and Service/Support Booklet provided with your NetServer documentation for the warranty limitations, customer responsibilities, and other terms and conditions. Hardware Accessories Limited Warranty An HP NetServer Hardware Accessory is an HP hardware product that is specifically - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 92
Chapter 9 Warranty and Support HP Repair and Telephone Support Refer to the HP NetServer Warranty and Service/Support Booklet supplied with your HP NetServer documentation for instructions on how to obtain HP repair and telephone support. 86 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 93
10 Regulatory Information For regulatory information pertaining to this HP accessory, please refer to the regulatory section of the HP NetServer LXr 8500 Installation Guide. 87 - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 94
- HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 95
the LXr 8500, 71 anti-static service kit, 19 B back up data NetServer without covers, 7 static electricity, 7, 11 center support installing on LXr 8500, 44 picture, 16 removing from LXr 8000, 30 common installation problems HP DiagTools utility, 78 HP NetRAID, 82 HP NetServer Navigator CD-ROM - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 96
installing in LXr 8500, 42 picture, 15 removing from LXr 8000, 32 N NOS reinstalling, 81 verify maximum memory supported, 3 verify supported versions, 1 O overview of upgrade, 5 90 P PCI board guide latch, 73 PCI boards guidelines for installing, 70 PCI hold-down latch, 52, 71, 73 PCI slot cover - HP D5970A | HP Netserver LXr 8000 to LXr 8500 Upgrade Guide - Page 97
S serial number, 1 service calling for, 1 Setup utility, 77 static-dissipating work surface, 7 system event log, 10 T tools needed, 9 top cover installing on the LXr 8500, 75 Index picture,
HP NetServer
LXr 8000 to LXr 8500
Upgrade Guide
HP Part Number 5967-6669