Compaq ProLiant 1600 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenanc - Page 114

Continued

Page 114 highlights

3-60 Diagnostic Tools DAAD Diagnostic Messages Continued Message Description Controller DAAD did not find a valid restarted with a configuration signature to use signature of zero to get the data. Nonvolatile RAM may not be present (unconfigured) or the signature present in nonvolatile RAM may not match the signature on the controller. DAAD recorded DAAD found errors while errors attempting attempting to access physical to access: X drive X, believed to be operational. Message followed by specific information about the error. Disable command Posted writes have been issued disabled by the issuing of the Accelerator Disable command. This occurred because of an operating system device driver. Drive (bay) X The 210-megabyte hard drive needs replacing (DAAD Error 102) has firmware version 2.30 or 2.31. Drive Monitoring DAAD unable to get monitor features are unobtainable and performance data due to fatal command problem such as drive time-out, or unable to get data due to these features not supported on the controller. Drive Monitoring is The monitor and performance NOT enabled for features have not been drive bay X enabled. Drive time-out occurred on physical drive bay X DAAD issued a command to a physical drive and the command was never acknowledged. Drive (bay) X firmware needs Firmware on this physical drive is below the latest Recommended Action Run the System Configuration Utility to configure the controller and nonvolatile RAM. Replace the drive, or correct the condition that caused the error. Restart the system. Run the System Configuration Utility to reinitialize the array accelerator board. Replace the drive. Check for other errors (timeouts, etc.). If no other errors occur, upgrade the firmware to a version that supports monitor and performance, if desired. Run the System Configuration Utility to initialize the monitor and performance features. The drive or cable may be bad. Check the other error messages on the Diagnostics screen to determine resolution. Run the Options ROMPaq Utility to upgrade the drive

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3-60
Diagnostic Tools
DAAD Diagnostic Messages
Continued
Message
Description
Recommended Action
Controller
restarted with a
signature of zero
DAAD did not find a valid
configuration signature to use
to get the data. Nonvolatile
RAM may not be present
(unconfigured) or the
signature present in
nonvolatile RAM may not
match the signature on the
controller.
Run the System
Configuration Utility to
configure the controller and
nonvolatile RAM.
DAAD recorded
errors attempting
to access: X
DAAD found errors while
attempting to access physical
drive X, believed to be
operational. Message
followed by specific
information about the error.
Replace the drive, or
correct the condition that
caused the error.
Disable command
issued
Posted writes have been
disabled by the issuing of the
Accelerator Disable
command. This occurred
because of an operating
system device driver.
Restart the system. Run the
System Configuration Utility
to reinitialize the array
accelerator board.
Drive (bay) X
needs replacing
(DAAD Error 102)
The 210-megabyte hard drive
has firmware version 2.30 or
2.31.
Replace the drive.
Drive Monitoring
features are
unobtainable
DAAD unable to get monitor
and performance data due
to fatal command problem
such as drive time-out, or
unable to get data due to
these features not supported
on the controller.
Check for other errors (time-
outs, etc.). If no other errors
occur, upgrade the
firmware to a version that
supports monitor and
performance, if desired.
Drive Monitoring is
NOT enabled for
drive bay X
The monitor and performance
features have not been
enabled.
Run the System
Configuration Utility to
initialize the monitor and
performance features.
Drive time-out
occurred on
physical drive bay
X
DAAD issued a command to a
physical drive and the
command was never
acknowledged.
The drive or cable may be
bad. Check the other error
messages on the
Diagnostics screen to
determine resolution.
Drive (bay) X
firmware needs
Firmware on this physical drive
is below the latest
Run the Options ROMPaq
Utility to upgrade the drive