Compaq ProLiant 1600 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenanc - Page 62
Error Code, Audible, Beeps, L=Long, S=Short, Probable Source of, Problem, Action, Speed - Check
View all Compaq ProLiant 1600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
3-8 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 203-Memory None RAM failure. Address Error 205-Cache Memory Error None Cache memory error. 205-Option Cache Memory Error 206-Cache Controller Error None None Option cache memory error. Cache controller failure. 207-Invalid Memory Configuration Check DIMM [SIMM] Installation 208-Invalid Memory Speed - Check DIMM [SIMM] Installation None 1L, 1S 211-Cache Switch Set Incorrectly None 212-System Processor Failed/Mappe d out 213-Cache Size Error 1S None Memory module installed incorrectly. The speed of the memory is too slow, where: xx00 = expansion board SIMMs are too slow, or 00yy = system board SIMMs are too slow. xx and yy have corresponding bit set. Switch not set properly during installation or upgrade. Processor in slot x failed. Invalid optional cache size. Action Run Diagnostics. Replace failed assembly as indicated. Replace the processor board in the slot indicated. Replace the option cache board. Run Diagnostics. Replace failed assembly as indicated. Verify placement of memory modules. The speed of the memory modules must be 60 ns. Verify the speed of the memory modules installed and replace. Verify switch settings. Run Diagnostics and replace failed processor. Replace cache with 256K cache.