3-62 Diagnostic Tools DAAD Diagnostic Messages Continued Message Description Drive (bay) X RIS The copies of the RIS on this copy mismatch drive do not match. Drive (bay) X upload code not readable Duplicate write memory error Error occurred reading RIS copy from drive (bay) X FYI: Drive (bay) X is non-Compaq supplied Identify controller data did not match with NVRAM Identify logical drive data did not match with NVRAM Insufficient An error occurred while DAAD was trying to read the upload code information from this drive. Data could not be written to the array accelerator board in duplicate due to the detection of parity errors. This is not a data loss situation. An error occurred while DAAD was trying to read the RIS from this drive. The installed drive was not supplied by Compaq. The identify controller data from the array controller did not match with the information stored in nonvolatile RAM. This could occur if new, previously configured drives have been placed in a system that has also been previously configured. It could also occur if the firmware on the controller has been upgraded and the System Configuration Utility was not run. The identify unit data from the array controller did not match with the information stored in nonvolatile RAM. This could occur if new, previously configured drives have been placed in a system that has also been previously configured. The adapter does not have Recommended Action This drive may need to be replaced. Check for other errors. If there were multiple errors, this drive may need to be replaced. Replace the array accelerator board. If there were multiple errors, this drive may need to be replaced. If problems exist with this drive, replace it with a Compaq drive. Check the identify controller data under the Inspect Utility. If the firmware version field is the only thing different between the controller and nonvolatile RAM data, this is not a problem. Otherwise run the System Configuration Utility. Run the System Configuration Utility to configure the controller and nonvolatile RAM. Operate the system without

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3-62
Diagnostic Tools
DAAD Diagnostic Messages
Continued
Message
Description
Recommended Action
Drive (bay) X RIS
copy mismatch
The copies of the RIS on this
drive do not match.
This drive may need to be
replaced. Check for other
errors.
Drive (bay) X
upload code not
readable
An error occurred while DAAD
was trying to read the upload
code information from this
drive.
If there were multiple errors,
this drive may need to be
replaced.
Duplicate write
memory error
Data could not be written to
the array accelerator board in
duplicate due to the
detection of parity errors. This
is not a data loss situation.
Replace the array
accelerator board.
Error occurred
reading RIS copy
from drive (bay) X
An error occurred while DAAD
was trying to read the RIS from
this drive.
If there were multiple errors,
this drive may need to be
replaced.
FYI: Drive (bay) X is
non-Compaq
supplied
The installed drive was not
supplied by Compaq.
If problems exist with this
drive, replace it with a
Compaq drive.
Identify controller
data did not
match with
NVRAM
The identify controller data
from the array controller did
not match with the
information stored in
nonvolatile RAM. This could
occur if new, previously
configured drives have been
placed in a system that has
also been previously
configured. It could also
occur if the firmware on the
controller has been upgraded
and the System Configuration
Utility was not run.
Check the identify
controller data under the
Inspect Utility. If the
firmware version field is the
only thing different
between the controller and
nonvolatile RAM data, this is
not a problem. Otherwise
run the System
Configuration Utility.
Identify logical
drive data did not
match with
NVRAM
The identify unit data from the
array controller did not match
with the information stored in
nonvolatile RAM. This could
occur if new, previously
configured drives have been
placed in a system that has
also been previously
configured.
Run the System
Configuration Utility to
configure the controller and
nonvolatile RAM.
Insufficient
The adapter does not have
Operate the system without