Compaq ProLiant 1600 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenanc - Page 72
Fixed Disk Port, Conflict. Internal
View all Compaq ProLiant 1600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
3-18 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1769-Slot x None SMART-2 Controller Drive Array - error. Drive(s) disabled due to failure during expand. Select F1 to continue with logical drives disabled. Select F2 to accept data loss and to re- enable logical drives. 1771-Primary None Internal and external Disk Port hard drive controllers Address are both assigned to Assignment the primary address. Conflict 1772- None Address Assignment Secondary Disk Conflict. Internal and Port Address external hard drive Assignment Conflict controllers are both assigned to the secondary address. 1773-Primary None Fixed Disk Port Fixed disk drive error. Assignment Conflict Action Data has been lost while expanding the array, therefore the drives have been temporarily disabled. Press F2 to accept the data loss and re-enable the logical drives. Restore data from backup. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run the System Configuration Utility and correct.