Compaq ProLiant 1600 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenanc - Page 70

Slot x Drive Array Option ROM is Not Programmed, Slot x Drive Array Option ROM Appears to Conflict

Page 70 highlights

3-16 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1764-Slot x Drive Array - Capacity Expansion Process is temporarily disabled (followed by one of the following): Expansion will resume when Array Accelerator has been reattached. Expansion will resume when Array Accelerator has been replaced. Expansion will resume when Array Accelerator RAM allocation is successful. Expansion will resume when Array Accelerator battery reaches full charge. Expansion will resume when automatic data recovery has been completed. 1765-Slot x Drive Array Option ROM Appears to Conflict With an ISA Card. ISA cards with 16-bit memory cannot be configured in memory range C0000 to DFFFF along with the SMART-2/E 8-bit Option ROM due to EISA bus limitations. Please remove or reconfigure your ISA card. 1766-Slot x Drive Array requires System ROM Upgrade. Run Systems ROMPaq Utility. 1767-Slot x Drive Array Option ROM is Not Programmed Correctly or may Conflict with the Memory Address Range of an ISA Card. Check the Memory Address Configuration of installed ISA Card(s) or run Options ROMPaq Utility to attempt SMART-2/E Option ROM Reprogramming. 1768-Slot x Drive Array Resuming logical drive expansion process. None SMART-2 Controller error. Action Reattach or replace Array Accelerator, wait until the Array Accelerator batteries have charged, or for Automatic Data Recovery to complete, as indicated. Remove or reconfigure conflicting ISA cards. Disable " shared memory" on any ISA network cards that may be installed. Run the latest Systems ROMPaq Utility to upgrade your System ROMs. Remove or reconfigure conflicting ISA cards, especially any cards that are not recognized by the System Configuration Utility. Try reprogramming the SMART-2/E Controller's ROMs using the latest Options ROMPaq (version 2.29 or higher). No action required. Appears whenever a controller reset or power cycle occurs while array expansion is in progress.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168

.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
.
3-16
Diagnostic Tools
POST Error Messages
Continued
Error Code
Audible
Beeps
L=Long
S=Short
Probable Source of
Problem
Action
1764-Slot x Drive Array - Capacity Expansion Process is
temporarily disabled (followed by one of the following):
Expansion will resume when Array Accelerator has been
reattached.
Expansion will resume when Array Accelerator has been
replaced.
Expansion will resume when Array Accelerator RAM
allocation is successful.
Expansion will resume when Array Accelerator battery
reaches full charge.
Expansion will resume when automatic data recovery
has been completed.
Reattach or replace
Array Accelerator, wait
until the Array
Accelerator batteries
have charged, or for
Automatic Data
Recovery to complete,
as indicated.
1765-Slot x Drive Array Option ROM Appears to Conflict
With an ISA Card. ISA cards with 16-bit memory cannot
be configured in memory range C0000 to DFFFF along
with the SMART-2/E 8-bit Option ROM due to EISA bus
limitations. Please remove or reconfigure your ISA card.
Remove or reconfigure
conflicting ISA cards.
Disable “shared
memory” on any ISA
network cards that may
be installed.
1766-Slot x Drive Array requires System ROM Upgrade.
Run Systems ROMPaq Utility.
Run the latest Systems
ROMPaq Utility to
upgrade your System
ROMs.
1767-Slot x Drive Array Option ROM is Not Programmed
Correctly or may Conflict with the Memory Address
Range of an ISA Card. Check the Memory Address
Configuration of installed ISA Card(s) or run Options
ROMPaq Utility to attempt SMART-2/E Option ROM
Reprogramming.
Remove or reconfigure
conflicting ISA cards,
especially any cards
that are not recognized
by the System
Configuration Utility. Try
reprogramming the
SMART-2/E Controller’s
ROMs using the latest
Options ROMPaq
(version 2.29 or higher).
1768-Slot x
Drive Array -
Resuming
logical drive
expansion
process.
None
SMART-2 Controller
error.
No action required.
Appears whenever a
controller reset or
power cycle occurs
while array expansion is
in progress.