Compaq ProLiant 1600 Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenanc - Page 66
Server Manager/R, COM2, COM3 or
View all Compaq ProLiant 1600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 66 highlights
3-12 Diagnostic Tools POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1151-Com Port 2S Both external and 1 Address internal serial ports Assignment are assigned to Conflict COM1. 1152-Com Port 2S Both external and 2, 3, or 4 internal serial ports Address are assigned to Assignment COM2, COM3 or Conflict COM4. 1600-Server None Server Manager/R Manager/R board failure. Error Failure code displays after error message. 1610- 2S Ambient system Temperature temperature too hot. violation detected. Waiting for system to cool 1611-Fan 2S Required fan not failure installed or spinning. detected 1612-Primary 2S Primary power supply power supply has failed. failure 1613-Low None Real time clock System Battery system battery is running low on power. 1614- None Redundant fan failure detected 1701-SCSI None A test on the Fast Controller SCSI-2 Controller failure failed. Action Run the System Configuration Utility and correct. Run the System Configuration Utility and correct. Run Diagnostics. Replace failed assembly as indicated. Check fan in system environment. Check fans. Replace power supply as soon as possible. Run Diagnostics. Replace failed assembly as indicated. Run Diagnostics. Replace failed assembly as indicated.