3-23 POST Error Messages Continued Error Code Audible Beeps L=Long S=Short Probable Source of Problem 1789-Drive Not None Cable or hard drive Responding, failure. Physical Drive Check cables or replace physical drive X. Select "F1" to continue - drive array will remain disabled. Select "F2" to fail drive(s) that are not responding - Interim Recovery Mode will be enabled if configured for fault tolerance. 1790-Disk 0 None Hard drive error or Configuration wrong drive type. Error 1791-Disk 1 Error None Hard drive error or wrong drive type. Action 1. Check the cable connections. 2. If cables are connected, replace the drive. 3. If you do not want to replace the drives now, press F2. Run the System Configuration Utility and Diagnostics and correct. Run the System Configuration Utility and Diagnostics and correct. Compaq ProLiant 1600 and ProLiant 1200 Servers Maintenance and Service Guide