Diagnostic Tools 3-47 Table 3-21 ADU Diagnostic Messages continued Message Description Controller reported POST error. Error Code: X The controller returned an error from its internal Power-On Self-Tests. Controller restarted with a signature of zero. ADU did not find a valid configuration signature to use to get the data. Nonvolatile RAM may not be present (unconfigured) or the signature present in nonvolatile RAM may not match the signature on the controller. Disable command issued. Posted-writes have been disabled by the issuing of the Accelerator Disable command. This occurred because of an operating system device driver. Drive (bay) X firmware needs upgrading. Firmware on this physical drive is below the latest recommended version. Drive (bay) X has insufficient capacity for its configuration. Drive has insufficient capacity to be used in this logical drive configuration. Drive (bay) X has invalid M&P stamp. Physical drive has invalid monitor and performance data. Drive (bay) X has loose cable. The array controller could not communicate with this drive at power up. This drive has not previously failed. Drive (bay) X is a replacement drive. Drive (bay) X is a replacement drive marked OK. Drive (bay) X is failed. Drive (bay) X is undergoing drive recovery. Drive (bay) X needs replacing Drive (bay) X upload code not readable This drive has been replaced. This message displays if a drive is replaced in a fault tolerant logical volume. This drive has been replaced and marked OK by the firmware. This may occur if a drive has an intermittent failure (for example, if a drive has previously failed, then when ADU is run, the drive starts working again). The indicated physical drive has failed. This drive is being rebuilt from the corresponding mirror or parity data. The 210-megabyte hard drive has firmware version 2.30 or 2.31. An error occurred while ADU was trying to read the upload code information from this drive. Recommended Action Replace the controller. Run the System Configuration Utility to configure the controller and nonvolatile RAM. Restart the system. Run the Array Configuration Utility to reinitialize the array accelerator board. Run the Options ROMPaq Utility to upgrade the drive firmware to the latest revision. Replace this drive with a larger capacity drive. Run the System Configuration Utility to properly initialize this drive. Check all cable connections first. The cables could be bad, loose, or disconnected. Turn on the system and attempt to reconnect signal/power cable to the drive. If this does not work, replace the cable. If that does not work, the drive may need to be replaced. If the replacement was intentional, allow the drive to rebuild. Replace the drive. Replace the drive. Normal operations should occur. Replace the drive. If there were multiple errors, this drive may need to be replaced. continued