Compaq ProLiant 8500 ProLiant 8500 Servers Maintenance and Service Guide - Page 125

Run the Options ROMPaq Utility to upgrade, Run the System Configuration Utility

Page 125 highlights

Diagnostic Tools 3-47 Table 3-21 ADU Diagnostic Messages continued Message Description Controller reported POST error. Error Code: X The controller returned an error from its internal Power-On Self-Tests. Controller restarted with a signature of zero. ADU did not find a valid configuration signature to use to get the data. Nonvolatile RAM may not be present (unconfigured) or the signature present in nonvolatile RAM may not match the signature on the controller. Disable command issued. Posted-writes have been disabled by the issuing of the Accelerator Disable command. This occurred because of an operating system device driver. Drive (bay) X firmware needs upgrading. Firmware on this physical drive is below the latest recommended version. Drive (bay) X has insufficient capacity for its configuration. Drive has insufficient capacity to be used in this logical drive configuration. Drive (bay) X has invalid M&P stamp. Physical drive has invalid monitor and performance data. Drive (bay) X has loose cable. The array controller could not communicate with this drive at power up. This drive has not previously failed. Drive (bay) X is a replacement drive. Drive (bay) X is a replacement drive marked OK. Drive (bay) X is failed. Drive (bay) X is undergoing drive recovery. Drive (bay) X needs replacing Drive (bay) X upload code not readable This drive has been replaced. This message displays if a drive is replaced in a fault tolerant logical volume. This drive has been replaced and marked OK by the firmware. This may occur if a drive has an intermittent failure (for example, if a drive has previously failed, then when ADU is run, the drive starts working again). The indicated physical drive has failed. This drive is being rebuilt from the corresponding mirror or parity data. The 210-megabyte hard drive has firmware version 2.30 or 2.31. An error occurred while ADU was trying to read the upload code information from this drive. Recommended Action Replace the controller. Run the System Configuration Utility to configure the controller and nonvolatile RAM. Restart the system. Run the Array Configuration Utility to reinitialize the array accelerator board. Run the Options ROMPaq Utility to upgrade the drive firmware to the latest revision. Replace this drive with a larger capacity drive. Run the System Configuration Utility to properly initialize this drive. Check all cable connections first. The cables could be bad, loose, or disconnected. Turn on the system and attempt to reconnect signal/power cable to the drive. If this does not work, replace the cable. If that does not work, the drive may need to be replaced. If the replacement was intentional, allow the drive to rebuild. Replace the drive. Replace the drive. Normal operations should occur. Replace the drive. If there were multiple errors, this drive may need to be replaced. continued

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

Diagnostic Tools
3-47
Table 3-21
ADU Diagnostic Messages
continued
Message
Description
Recommended Action
Controller reported
POST error.
Error Code: X
The controller returned an error from
its internal Power-On Self-Tests.
Replace the controller.
Controller restarted
with a signature of
zero.
ADU did not find a valid configuration
signature to use to get the data.
Nonvolatile RAM may not be present
(unconfigured) or the signature
present in nonvolatile RAM may not
match the signature on the controller.
Run the System Configuration Utility to
configure the controller and nonvolatile
RAM.
Disable command
issued.
Posted-writes have been disabled by
the issuing of the Accelerator Disable
command. This occurred because of
an operating system device driver.
Restart the system. Run the Array
Configuration Utility to reinitialize the array
accelerator board.
Drive (bay) X
firmware needs
upgrading.
Firmware on this physical drive is
below the latest recommended
version.
Run the Options ROMPaq Utility to upgrade
the drive firmware to the latest revision.
Drive (bay) X has
insufficient capacity
for its configuration.
Drive has insufficient capacity to be
used in this logical drive configuration.
Replace this drive with a larger capacity
drive.
Drive (bay) X has
invalid M&P stamp.
Physical drive has invalid monitor and
performance data.
Run the System Configuration Utility to
properly initialize this drive.
Drive (bay) X has
loose cable.
The array controller could not
communicate with this drive at power
up. This drive has not previously
failed.
Check all cable connections first. The
cables could be bad, loose, or
disconnected. Turn on the system and
attempt to reconnect signal/power cable to
the drive. If this does not work, replace the
cable. If that does not work, the drive may
need to be replaced.
Drive (bay) X is a
replacement drive.
This drive has been replaced. This
message displays if a drive is replaced
in a fault tolerant logical volume.
If the replacement was intentional, allow
the drive to rebuild.
Drive (bay) X is a
replacement drive
marked OK.
This drive has been replaced and
marked OK by the firmware. This may
occur if a drive has an intermittent
failure (for example, if a drive has
previously failed, then when ADU is
run, the drive starts working again).
Replace the drive.
Drive (bay) X is
failed.
The indicated physical drive has failed.
Replace the drive.
Drive (bay) X is
undergoing drive
recovery.
This drive is being rebuilt from the
corresponding mirror or parity data.
Normal operations should occur.
Drive (bay) X needs
replacing
The 210-megabyte hard drive has
firmware version 2.30 or 2.31.
Replace the drive.
Drive (bay) X upload
code not readable
An error occurred while ADU was
trying to read the upload code
information from this drive.
If there were multiple errors, this drive
may need to be replaced.
continued