Compaq ProLiant 8500 ProLiant 8500 Servers Maintenance and Service Guide - Page 167
System Unit, Table 5-1, System Unit Specifications - btu
View all Compaq ProLiant 8500 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 167 highlights
5-2 Compaq ProLiant 8500 Server Maintenance and Service Guide System Unit Table 5-1 System Unit Specifications Dimensions Height Width Depth Weight (no drives and two power supplies) Temperature range Operating Nonoperating Shipping Maximum wet bulb temperature Input requirements (per power supply) Rated input voltage Rated input frequency Rated input current Rated input power Power supply output power (per power supply) Rated steady-state power Maximum peak power Relative humidity range (noncondensing) Operating Nonoperating Heat dissipation Maximum heat output (system is configured to draw maximum power) 30.83 cm (12.14 inches) 48.26 cm (19.0 inches) 69.72 cm (27.45 inches) 50 kg (110 lb) 10° to 35°C (50° to 90°F) -30° to 60°C (-20° to 140°F) -30° to 50°C (-22° to 122°F) 38.7°C (101.7°F) Low Range/High Range 100 to 120V/200 to 240V 47 to 63 Hz/47 to 63 Hz 8 A/10 A 740W @ 110V/1700W @ 220V Low Range/High Range 500W/1150W 540W/1150W 20% to 80% 5% to 90% 5309 BTU per hr/1555W