Compaq ProLiant 8500 ProLiant 8500 Servers Maintenance and Service Guide - Page 167

System Unit, Table 5-1, System Unit Specifications - btu

Page 167 highlights

5-2 Compaq ProLiant 8500 Server Maintenance and Service Guide System Unit Table 5-1 System Unit Specifications Dimensions Height Width Depth Weight (no drives and two power supplies) Temperature range Operating Nonoperating Shipping Maximum wet bulb temperature Input requirements (per power supply) Rated input voltage Rated input frequency Rated input current Rated input power Power supply output power (per power supply) Rated steady-state power Maximum peak power Relative humidity range (noncondensing) Operating Nonoperating Heat dissipation Maximum heat output (system is configured to draw maximum power) 30.83 cm (12.14 inches) 48.26 cm (19.0 inches) 69.72 cm (27.45 inches) 50 kg (110 lb) 10° to 35°C (50° to 90°F) -30° to 60°C (-20° to 140°F) -30° to 50°C (-22° to 122°F) 38.7°C (101.7°F) Low Range/High Range 100 to 120V/200 to 240V 47 to 63 Hz/47 to 63 Hz 8 A/10 A 740W @ 110V/1700W @ 220V Low Range/High Range 500W/1150W 540W/1150W 20% to 80% 5% to 90% 5309 BTU per hr/1555W

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

5-2
Compaq ProLiant 8500 Server Maintenance and Service Guide
System Unit
Table 5-1
System Unit Specifications
Dimensions
Height
30.83 cm (12.14 inches)
Width
48.26 cm (19.0 inches)
Depth
69.72 cm (27.45 inches)
Weight (no drives and two power supplies)
50 kg (110 lb)
Temperature range
Operating
10
°
to 35
°
C (50
°
to 90
°
F)
Nonoperating
-30
°
to 60
°
C (-20
°
to 140
°
F)
Shipping
-30
°
to 50
°
C (-22
°
to 122
°
F)
Maximum wet bulb temperature
38.7
°
C (101.7
°
F)
Input requirements (per power supply)
Low Range/High Range
Rated input voltage
100 to 120V/200 to 240V
Rated input frequency
47 to 63 Hz/47 to 63 Hz
Rated input current
8 A/10 A
Rated input power
740W @ 110V/1700W @ 220V
Power supply output power (per power supply)
Low Range/High Range
Rated steady-state power
500W/1150W
Maximum peak power
540W/1150W
Relative humidity range (noncondensing)
Operating
20% to 80%
Nonoperating
5% to 90%
Heat dissipation
Maximum heat output (system is configured
to draw maximum power)
5309 BTU per hr/1555W