Compaq Integrated Smart Array Controller, Table 5-8

Page 173 highlights

5-8 Compaq ProLiant 8500 Server Maintenance and Service Guide Compaq Integrated Smart Array Controller Table 5-8 Compaq Integrated Smart Array Controller Specifications Temperature range Operating Shipping Relative humidity range (non-condensing) Operating Nonoperating Maximum drives supported Logical drives supported Simultaneous drive transfer channels Data transfer method Total transfer rate SCSI electrical interface PCI bus transfer rate (maximum) SCSI port connectors (internal and external) Protocol SCSI electrical interface Software upgradable firmware Read cache Reliability features Cache battery backup Online capacity expansion Logical drive capacity extension Online RAID level migration Online stripe size migration Automatic data recovery Distributed data guarding (RAID 5) Data guarding (RAID 4) Data mirroring (RAID 1) Drive striping (RAID 0, 0 + 1) 10° to 35°C (50° to 95°F) -30° to 60°C (-22° to 140°F) 20% to 80% 5% to 90% 4 32 1 64-bit PCI bus master 80 MB/s (80 MB/s per channel) Low-voltage differential (LVD) and singleended 133 MB/s PCI 64D Extended SCSI connector Wide Ultra2 SCSI Low-voltage differential Yes 12 MB No Yes Yes Yes Yes Yes Yes No Yes Yes

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

5-8
Compaq ProLiant 8500 Server Maintenance and Service Guide
Compaq Integrated Smart Array Controller
Table 5-8
Compaq Integrated Smart Array Controller Specifications
Temperature range
Operating
10
°
to 35
°
C (50
°
to 95
°
F)
Shipping
-30
°
to 60
°
C (-22
°
to 140
°
F)
Relative humidity range (non-condensing)
Operating
20% to 80%
Nonoperating
5% to 90%
Maximum drives supported
4
Logical drives supported
32
Simultaneous drive transfer channels
1
Data transfer method
64-bit PCI bus master
Total transfer rate
80 MB/s (80 MB/s per channel)
SCSI electrical interface
Low-voltage differential (LVD) and single-
ended
PCI bus transfer rate (maximum)
133 MB/s
SCSI port connectors (internal and external)
PCI 64D Extended SCSI connector
Protocol
Wide Ultra2 SCSI
SCSI electrical interface
Low-voltage differential
Software upgradable firmware
Yes
Read cache
12 MB
Reliability features
Cache battery backup
Online capacity expansion
Logical drive capacity extension
Online RAID level migration
Online stripe size migration
Automatic data recovery
Distributed data guarding (RAID 5)
Data guarding (RAID 4)
Data mirroring (RAID 1)
Drive striping (RAID 0, 0 + 1)
No
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
Yes