HP CP6015dn Service Manual - Page 423
Optional Tray Connection, Duplexer Connection
UPC - 883585363018
View all HP CP6015dn manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 423 highlights
Table 7-4 Control-panel messages (continued) Control panel message Description Recommended action 56.02 ERROR To continue turn off then on The product has experienced an output error. 1. Follow the solutions for BAD DUPLEXER CONNECTION or BAD OPTIONAL TRAY CONNECTION. 56.X ERROR To continue turn off then on A temporary printing error has occurred. Turn the product off, and then turn the product on. If this message persists, contact an HPauthorized service or support provider. (See the HP Support flyer, or go to www.hp.com/ support/cljcp6015.) 57.01 ERROR To continue turn off then on The laser/scanner-unit cooling fan (FM1) has 1. experienced an error. Reconnect the connectors of the laser/ scanner-unit cooling fan (J1916) and the DC controller PCA (J132). 2. Measure the voltage between the connector J132-4 and J132-6 on the DC controller PCA right after the product is turned on. If the voltage changes from 0V to approximately 24V, replace the laser/scanner-unit cooling fan. 57.01 ERROR To continue turn off then on The VOC fan (FM4) has experienced an error. 1. Reconnect the connectors of the VOC fan (J1921) and the DC controller PCA (J103). 2. Measure the voltage between the connector J103-4 and J103-6 on the DC controller PCA right after the product is turned on. If the voltage changes from 0V to approximately 24V, replace the VOC fan. 57.03 ERROR To continue turn off then on The fuser cooling fan (FM2) has experienced 1. an error. Reconnect the connectors of the fuser cooling fan (J1917) and the DC controller PCA (J132). 2. Measure the voltage between the connector J132-7 and J132-9 on the DC controller PCA right after the product is turned on. If the voltage changes from 0V to approximately 24V, replace the cartridge area cooling fan. 57.04 ERROR To continue turn off then on The cartridge area cooling fan (FM3) has experienced an error. 1. Reconnect the connectors of the cartridge area cooling fan (J1915) and the DC controller PCA (J132). 2. Measure the voltage between the connector J132-1 and J132-3 on the DC controller PCA right after the product is turned on. If the voltage changes from 0V to approximately 24V, replace the cartridge area cooling fan. 57.05 ERROR To continue turn off then on The low-voltage power supply cooling fan (FM5) has experienced an error. 1. Reconnect the connectors of the lowvoltage power supply cooling fan (J2), low-voltage power supply (J6) and the DC controller PCA (J102). 2. Measure the voltage between the connector J2-1 and J2-3 on the lowvoltage power supply cooling fan right ENWW Control-panel messages 381