Table D-2, Is the System Power LED Amber?, Answer, Possible Reasons, Possible Solutions
UPC - 613326960790
View all HP ML330 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 116 highlights
Server Specific Troubleshooting Table D-2: Is the System Power LED Amber? Answer No Yes Possible Reasons The server is not connected to AC power or no AC power is available. The power supply may not be inserted properly, it may have a damaged connector, or it may have failed. A broken connection exists between the following: • Power supply and system board • System board and power button/LED assembly • The power supply, system board, and/or power button/LED assembly may need to be replaced. If the system power LED is amber: 1. Press the Power On/Standby button. 2. Refer to Table D-3. Possible Solutions Be sure that the power cord is connected to the power supply. Be sure that the power supply is undamaged and is fully seated. Be sure that the power supply cables are connected to the system board. Be sure that the power button/LED cable is connected to the system board and power button/LED assembly. Be sure that all pins on connectors and components are straight. Refer to the Servers Troubleshooting Guide for further options regarding power and general hardware problems. Contact the authorized service provider for assistance. HP ProLiant ML330 Generation 3 Server Setup and Installation Guide D-5