HP ML330 HP ProLiant ML330 Generation 3 Server Setup and Installation Guide - Page 118
Table D-4, Is the Internal Health LED Green
UPC - 613326960790
View all HP ML330 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 118 highlights
Server Specific Troubleshooting Table D-4: Is the Internal Health LED Green? Answer No, it is amber No, it is red Yes Possible Reasons Possible Solutions A processor or DIMM is in pre-failure condition. Use amber failure LEDs to identify: • Missing components • Degraded components • Failed components • Improperly installed components Contact the authorized service provider for replacement parts and service. A processor, PPM, or fan has failed. Use amber failure LEDs to identify: Processor 1 is not installed. • Missing components A processor is an unsupported type. Processors are mismatched (speed and/or type). A DIMM has experienced a multibit error. No valid memory is in the system. The SCSI cabling or terminator configuration is incorrect on the SCSI controller. • Degraded components • Failed components • Improperly installed components Contact the authorized service provider for replacement parts and service. An overtemperature condition has occurred. If the internal health LED is green, refer to Table D-5. HP ProLiant ML330 Generation 3 Server Setup and Installation Guide D-7