Floppy Port Address, Run Computer Setup.
View all HP Point of Sale rp5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
POST Error Messages Numeric Codes and Text Messages (Continued) Code/Message 605-Diskette Drive Type Error 610-External Storage Device Failure 611-Primary Floppy Port Address Assignment Conflict 612-Secondary Floppy Port Address Assignment Conflict 660-Display cache is detected unreliable 916-Thermal Sensor from Processor Heatsink is not Connected 917-Expansion Riser not Detected Probable Cause Mismatch in drive type. External tape drive not connected. Configuration error. Configuration error. Integrated graphics controller display cache is not working properly and will be disabled. Processor heatsink cable not connected to system board. Riser board not seated or not installed. Recommended Action 1. Run Computer Setup. 2. Disconnect any other diskette controller devices (tape drives). 3. Clear CMOS. (See Appendix B, "Password Security and Resetting CMOS.") Reinstall tape drive or press F1 and allow system to reconfigure without the drive. Run Computer Setup. 1. Run Computer Setup. 2. Remove expansion cards. 3. Clear CMOS. (See Appendix B, "Password Security and Resetting CMOS.") Replace system board if minimal graphics degrading is an issue. Reseat or replace the processor heatsink cable going to the system board. Install riser board if missing or remove and reseat to ensure good connection. Troubleshooting Guide www.hp.com A-7