To run a functional test on ports 0
View all HP StorageWorks 4/16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 360 highlights
2 miniCycle Running minicycle One moment please ... Path 0 ... Spinning ... Path 1 ... Spinning ... Path 2 ... Spinning ... Path 3 ... Spinning ... Path 4 ... Spinning ... Path 5 ... Spinning ... Path 6 ... Spinning ... Path 7 ... Spinning ... Test Complete: minicycle Pass 1 of 1 Duration 0 hr, 1 min & 4 sec (0:1:4:409). passed. To run a functional test on ports 0, 1, 2, and 8 using port loopback: switch:admin> minicycle -ports 0,1,2,8 -lb_mode 1 Back Plane Loop Back mode is ON. Running mini Cycle One moment please ... Path 0 ... Spinning ... Path 1 ... skipped. Path 2 ... skipped. Path 3 ... skipped. Path 4 ... skipped. Path 5 ... skipped. Path 6 ... Spinning ... Path 7 ... Spinning ... Test Complete: "minicycle" Pass 1 of 1 Duration 0 hr, 0 min & 23 sec (0:0:23:100). passed. Diagnostics When it detects failure(s), the test reports one or more of the following error messages: DATA EPI1_STATUS_ERR ERR_STATS_2LONG ERR_STATS_BADEOF ERR_STATS_BADOS ERR_STATS_C3DISC ERR_STATS_CRC ERR_STATS_ENCIN ERR_STATS_ENCOUT ERR_STATS_TRUNC ERR_STAT_2LONG ERR_STAT_BADEOF ERR_STAT_BADOS ERR_STAT_C3DISC ERR_STAT_CRC ERR_STAT_ENCIN ERR_STAT_ENCOUT ERR_STAT_TRUNC FDET_PERR FINISH_MSG_ERR FTPRT_STATUS_ERR INIT 334 Fabric OS Command Reference 53-1000599-01