HP StorageWorks 4/16 Brocade OS Command Reference Manual Supporting Fabric OS - Page 629
supportFfdc, Synopsis, disable, enable, Description, Operands, Examples, See Also
View all HP StorageWorks 4/16 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 629 highlights
supportFfdc 2 supportFfdc Modifies or displays first-fault data capture (FFDC) daemon. Synopsis supportffdc [--disable | --enable | --show] Description Use this command to disable or enable the FFDC events, or display the current configuration. If disabled, the daemon does not capture any data even when a message with FFDC attributes is logged. FFDC is enabled by default. The execution of this command is subject to Admin Domain restrictions that may be in place. Operands This command has the following operands: --disable Disables the FFDC. --enable Enables the FFDC. --show Displays the FFDC configuration parameters. When executed without operands, the command prints the usage. Examples To display the FFDC configuration: switch:admin> supportffdc --show First Failure Data Capture (FFDC) is disabled. To enable the FFDC events: switch:admin> supportffdc --enable First Failure Data Capture (FFDC) is enabled. See Also none Fabric OS Command Reference 603 53-1000599-01