HP Visualize J5000 hp Visualize J5000, J7000 workstations service handbook (a4 - Page 37
Table 2-1., Environmental Specifications
View all HP Visualize J5000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Table 2-1. Environmental Specifications Type Specification Altitude Operating Non-operating 0-15,000 ft 40,000 ft DC magnetic field Operating Non-operating
2–2
Environmental/Installation/PM
Table 2–1.
Environmental Specifications
Type
Specification
Altitude
Operating
0–15,000 ft
Non-operating
40,000 ft
DC magnetic field
Operating
<5 Gauss
Non-operating
<2 Gauss @ 7 feet
Electromagnetic Interference (EMI)
Emissions
FCC Class B CISPR B
Susceptibility
FCC Class B CISPR B
Electrostatic Discharge
Air discharge
0–16 kV, no effect
Contact discharge
0–3 kV, no effect
Humidity (Non-condensing)
Operating
95%
Leakage Current
less than 3.5 mA
Temperature
Operating
+5 to +40
°
C
Non-operating
–40 to +70
°
C
Shock
Operating
20g at 3ms, 1/2 sine in normal axis with
no hard errors
Non-operating
80g at 3ms, 1/2 sine, normal axis
Vibration
Operating random
0.21 G rms, 5–50 Hz
Swept sine survival
0.5 G peak, 5–500 Hz
Random survival
2.09 G rms, 5–500 Hz
Acoustics
<5 bels 5–30
°
C
<6 bels 30–40
°
C