IBM 8676 Hardware Maintenance Manual - Page 42

Windows, driver, messages

Page 42 highlights

Table 4. NetWare or IntraNetWare system ODI driver teaming messages for the Ethernet controller (continued) Message Description Requested number of Secondary cards are not found. Explanation: The number of adapters specified in the bind command could not be located. Action: Verify the numbers and slot locations of the adapters to be bound. If the problem remains, contact the network supplier. Failed to create AFT group. Make Explanation: Binding of protocol failed. Protocol is either not bound to any sure that the drivers for supported adapter or is bound to more than one adapter in the group. adapters are loaded, primary adapter is bound to protocols, and secondary Action: Ensure that the protocol is bound to only one adapter in an AFT adapter is not bound to any protocols. team. Error identifying slot numbers for the Explanation: The mapping between the board name entered and the slot specified board names. number for an adapter could not be established. Action: Check the board name for the adapter before issuing the bind command. If the problem remains, contact the network supplier. Cannot unbind specified slot from AFT group. Make sure that the slot you specified is for the primary adapter in an AFT group. Explanation: The number entered in the unbind command was not the primary adapter in an AFT group. Action: Reissue the unbind command and specify the slot number for the primary adapter. LAN adapter at slot nnnn (Port 0xaa) failed to reset. Check the state of the adapter. Explanation: The adapter that you specified could not be initialized. Action: 1. Load the driver for the supported adapter. 2. Check that the adapter is seated properly in the slot and try loading the AFT module again. If the problem remains, contact the network supplier. AFT is not supported on this version of NetWare. Explanation: The NetWare on the server is not a version supported by AFT. Action: Load and bind AFT only on supported versions of NetWare (currently version 5.1 and above). Failed to allocate resources tags. Explanation: An unknown error has occurred when trying to allocate needed resources for the AFT module. Please unload all LAN drivers before unloading AFT.NLM. Action: Check system configuration. If the problem remains, contact the network supplier. Explanation: An attempt was made to unload the AFT.NLM module before unloading the adapter driver. Action: Unload the adapter driver before unloading the AFT module. NDIS 4.0 (Windows NT) driver messages This section explains the error messages for the NDIS drivers. The explanation and recommended action are included with each message. Note: Although the term ″adapter″ is used in these messages, the messages might also apply to the integrated Ethernet controller on the system board. 32 xSeries 335 Type 8676, Type 8830: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172

Table
4.
NetWare
or
IntraNetWare
system
ODI
driver
teaming
messages
for
the
Ethernet
controller
(continued)
Message
Description
Requested
number
of
Secondary
cards
are
not
found.
Explanation:
The
number
of
adapters
specified
in
the
bind
command
could
not
be
located.
Action:
Verify
the
numbers
and
slot
locations
of
the
adapters
to
be
bound.
If
the
problem
remains,
contact
the
network
supplier.
Failed
to
create
AFT
group.
Make
sure
that
the
drivers
for
supported
adapters
are
loaded,
primary
adapter
is
bound
to
protocols,
and
secondary
adapter
is
not
bound
to
any
protocols.
Explanation:
Binding
of
protocol
failed.
Protocol
is
either
not
bound
to
any
adapter
or
is
bound
to
more
than
one
adapter
in
the
group.
Action:
Ensure
that
the
protocol
is
bound
to
only
one
adapter
in
an
AFT
team.
Error
identifying
slot
numbers
for
the
specified
board
names.
Explanation:
The
mapping
between
the
board
name
entered
and
the
slot
number
for
an
adapter
could
not
be
established.
Action:
Check
the
board
name
for
the
adapter
before
issuing
the
bind
command.
If
the
problem
remains,
contact
the
network
supplier.
Cannot
unbind
specified
slot
from
AFT
group.
Make
sure
that
the
slot
you
specified
is
for
the
primary
adapter
in
an
AFT
group.
Explanation:
The
number
entered
in
the
unbind
command
was
not
the
primary
adapter
in
an
AFT
group.
Action:
Reissue
the
unbind
command
and
specify
the
slot
number
for
the
primary
adapter.
LAN
adapter
at
slot
nnnn
(Port
0x
aa
)
failed
to
reset.
Check
the
state
of
the
adapter.
Explanation:
The
adapter
that
you
specified
could
not
be
initialized.
Action:
1.
Load
the
driver
for
the
supported
adapter.
2.
Check
that
the
adapter
is
seated
properly
in
the
slot
and
try
loading
the
AFT
module
again.
If
the
problem
remains,
contact
the
network
supplier.
AFT
is
not
supported
on
this
version
of
NetWare.
Explanation:
The
NetWare
on
the
server
is
not
a
version
supported
by
AFT.
Action:
Load
and
bind
AFT
only
on
supported
versions
of
NetWare
(currently
version
5.1
and
above).
Failed
to
allocate
resources
tags.
Explanation:
An
unknown
error
has
occurred
when
trying
to
allocate
needed
resources
for
the
AFT
module.
Action:
Check
system
configuration.
If
the
problem
remains,
contact
the
network
supplier.
Please
unload
all
LAN
drivers
before
unloading
AFT.NLM.
Explanation:
An
attempt
was
made
to
unload
the
AFT.NLM
module
before
unloading
the
adapter
driver.
Action:
Unload
the
adapter
driver
before
unloading
the
AFT
module.
NDIS
4.0
(Windows
NT)
driver
messages
This
section
explains
the
error
messages
for
the
NDIS
drivers.
The
explanation
and
recommended
action
are
included
with
each
message.
Note:
Although
the
term
adapter
is
used
in
these
messages,
the
messages
might
also
apply
to
the
integrated
Ethernet
controller
on
the
system
board.
32
xSeries
335
Type
8676,
Type
8830:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide