Intel E3300 Data Sheet - Page 17

Voltage and Current Specification

Page 17 highlights

Electrical Specifications 2.6 2.6.1 Table 3. Voltage and Current Specification Absolute Maximum and Minimum Ratings Table 3 specifies absolute maximum and minimum ratings only and lie outside the functional limits of the processor. Within functional operation limits, functionality and long-term reliability can be expected. At conditions outside functional operation condition limits, but within absolute maximum and minimum ratings, neither functionality nor long-term reliability can be expected. If a device is returned to conditions within functional operation limits after having been subjected to conditions outside these limits, but within the absolute maximum and minimum ratings, the device may be functional, but with its lifetime degraded depending on exposure to conditions exceeding the functional operation condition limits. At conditions exceeding absolute maximum and minimum ratings, neither functionality nor long-term reliability can be expected. Moreover, if a device is subjected to these conditions for any length of time then, when returned to conditions within the functional operating condition limits, it will either not function, or its reliability will be severely degraded. Although the processor contains protective circuitry to resist damage from static electric discharge, precautions should always be taken to avoid high static voltages or electric fields. Absolute Maximum and Minimum Ratings Symbol Parameter Min VCC Core voltage with respect to VSS -0.3 VTT FSB termination voltage with respect to VSS -0.3 TCASE Processor case temperature See Section 5 TSTORAGE Processor storage temperature -40 Max 1.45 1.45 See Section 5 85 Unit Notes1, 2 VV°C °C 3, 4, 5 NOTES: 1. For functional operation, all processor electrical, signal quality, mechanical and thermal specifications must be satisfied. 2. Excessive overshoot or undershoot on any signal will likely result in permanent damage to the processor. 3. Storage temperature is applicable to storage conditions only. In this scenario, the processor must not receive a clock, and no lands can be connected to a voltage bias. Storage within these limits will not affect the long-term reliability of the device. For functional operation, refer to the processor case temperature specifications. 4. This rating applies to the processor and does not include any tray or packaging. 5. Failure to adhere to this specification can affect the long term reliability of the processor. Datasheet 17

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100

Datasheet
17
Electrical Specifications
2.6
Voltage and Current Specification
2.6.1
Absolute Maximum and Minimum Ratings
Table 3
specifies absolute maximum and minimum ratings only and lie outside the
functional limits of the processor. Within functional operation limits, functionality and
long-term reliability can be expected.
At conditions outside functional operation condition limits, but within absolute
maximum and minimum ratings, neither functionality nor long-term reliability can be
expected. If a device is returned to conditions within functional operation limits after
having been subjected to conditions outside these limits, but within the absolute
maximum and minimum ratings, the device may be functional, but with its lifetime
degraded depending on exposure to conditions exceeding the functional operation
condition limits.
At conditions exceeding absolute maximum and minimum ratings, neither functionality
nor long-term reliability can be expected. Moreover, if a device is subjected to these
conditions for any length of time then, when returned to conditions within the
functional operating condition limits, it will either not function, or its reliability will be
severely degraded.
Although the processor contains protective circuitry to resist damage from static
electric discharge, precautions should always be taken to avoid high static voltages or
electric fields.
NOTES:
1.
For functional operation, all processor electrical, signal quality, mechanical and thermal
specifications must be satisfied.
2.
Excessive overshoot or undershoot on any signal will likely result in permanent damage to
the processor.
3.
Storage temperature is applicable to storage conditions only. In this scenario, the
processor must not receive a clock, and no lands can be connected to a voltage bias.
Storage within these limits will not affect the long-term reliability of the device. For
functional operation, refer to the processor case temperature specifications.
4.
This rating applies to the processor and does not include any tray or packaging.
5.
Failure to adhere to this specification can affect the long term reliability of the processor.
Table 3.
Absolute Maximum and Minimum Ratings
Symbol
Parameter
Min
Max
Unit
Notes
1, 2
V
CC
Core voltage with respect to
V
SS
–0.3
1.45
V
-
V
TT
FSB termination voltage with
respect to V
SS
–0.3
1.45
V
-
T
CASE
Processor case temperature
See
Section 5
See
Section 5
°C
-
T
STORAGE
Processor storage
temperature
–40
85
°C
3, 4, 5