Intel Q9400S Design Guidelines - Page 77

Appendix D, Case Temperature, Reference Metrology

Page 77 highlights

Case Temperature Reference Metrology Appendix D Case Temperature Reference Metrology D.1 D.2 Objective and Scope This appendix defines a reference procedure for attaching a thermocouple to the IHS of a 775-land LGA package for TC measurement. This procedure takes into account the specific features of the 775-land LGA package and of the LGA775 socket for which it is intended. The recommended equipment for the reference thermocouple installation, including tools and part numbers are also provided. In addition a video Thermocouple Attach Using Solder - Video CD-ROM is available that shows the process in real time. Supporting Test Equipment To apply the reference thermocouple attach procedure, it is recommended to use the equipment (or equivalent) given in the following table. Item Microscope DMM Thermal Meter Heater Block Heater Transformer Solder Flux Loctite* 498 Adhesive Adhesive Accelerator Kapton* Tape Thermocouple Description Part Number Measurement and Output Olympus* Light microscope or equivalent SZ-40 Digital Multi Meter for resistance measurement Fluke 79 Series Hand held thermocouple meter Multiple Vendors Solder Station (see note 1 for ordering information) Heater assembly to reflow solder on IHS WATLOW120V 150W Firerod Superior Powerstat transformer Miscellaneous Hardware 30330 0212G G1A38L12 05F857 Indium Corp. of America Alloy 57BI / 42SN / 1AG 0.010 Diameter Indium Corp. of America Super glue w/thermal characteristics 52124 5RMA 49850 Loctite* 7452 for fast glue curing 18490 For holding thermocouple in place Omega *,36 gauge, "T" Type (see note 2 for ordering information) Not Available OSK2K1280/5SR TC-TT-T-36-72 Thermal and Mechanical Design Guidelines 77

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124

Case Temperature Reference Metrology
Thermal and Mechanical Design Guidelines
77
Appendix D
Case Temperature
Reference Metrology
D.1
Objective and Scope
This appendix defines a reference procedure for attaching a thermocouple to the IHS
of a 775-land LGA package for T
C
measurement. This procedure takes into account the
specific features of the 775-land LGA package and of the LGA775 socket for which it is
intended. The recommended equipment for the reference thermocouple installation,
including tools and part numbers are also provided. In addition a video
Thermocouple
Attach Using Solder – Video CD-ROM
is available that shows the process in real time.
D.2
Supporting Test Equipment
To apply the reference thermocouple attach procedure, it is recommended to use the
equipment (or equivalent) given in the following table.
Item
Description
Part Number
Measurement and Output
Microscope
Olympus* Light microscope or equivalent
SZ-40
DMM
Digital Multi Meter for resistance measurement
Fluke 79 Series
Thermal Meter
Hand held thermocouple meter
Multiple Vendors
Solder Station (see note 1 for ordering information)
Heater Block
Heater assembly to reflow solder on IHS
30330
Heater
WATLOW120V 150W Firerod
0212G G1A38-
L12
Transformer
Superior Powerstat transformer
05F857
Miscellaneous Hardware
Solder
Indium Corp. of America
Alloy 57BI / 42SN / 1AG 0.010 Diameter
52124
Flux
Indium Corp. of America
5RMA
Loctite* 498
Adhesive
Super glue w/thermal characteristics
49850
Adhesive
Accelerator
Loctite* 7452 for fast glue curing
18490
Kapton* Tape
For holding thermocouple in place
Not Available
Thermocouple
Omega *,36 gauge, “T” Type
(see note 2 for ordering information)
OSK2K1280/5SR
TC-TT-T-36-72