Position Bead on the Groove Step, Detailed Thermocouple Bead Placement
UPC - 735858207973
View all Intel Q9400S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 87 highlights
Case Temperature Reference Metrology 11. While still at the microscope, press the wire down about 6mm [0.125"] from the thermocouple bead using the tweezers or your finger. Place a piece of Kapton* tape to hold the wire inside the groove (see Figure 38). Refer to Figure 39 for detailed bead placement. Figure 38. Position Bead on the Groove Step Kapton* tape Wire section into the groove to prepare for final bead placement Figure 39. Detailed Thermocouple Bead Placement TC Wire with Insulation IHS with Groove TC Bead Thermal and Mechanical Design Guidelines 87
Case Temperature Reference Metrology
Thermal and Mechanical Design Guidelines
87
11.
While still at the microscope, press the wire down about 6mm [0.125”] from the
thermocouple bead using the tweezers or your finger. Place a piece of Kapton*
tape to hold the wire inside the groove (see Figure 38). Refer to Figure 39 for
detailed bead placement.
Figure 38. Position Bead on the Groove Step
Figure 39. Detailed Thermocouple Bead Placement
TC Wire with Insulation
IHS with Groove
TC Bead
Wire section
into the
groove to
prepare for
final bead
placement
Kapton* tape