Intel Q9400S Design Guidelines - Page 84
Thermocouple Attach Procedure
UPC - 735858207973
View all Intel Q9400S manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 84 highlights
Case Temperature Reference Metrology D.5 Thermocouple Attach Procedure The procedure to attach a thermocouple with solder takes about 15 minutes to complete. Before proceeding turn on the solder block heater, as it can take up to 30 minutes to reach the target temperature of 153 - 155 °C. Note: To avoid damage to the TTV or processor ensure the IHS temperature does not exceed 155 °C. As a complement to the written procedure a video Thermocouple Attach Using Solder - Video CD-ROM is available. D.5.1 Thermocouple Conditioning and Preparation 1. Use a calibrated thermocouple as specified in Sections D.2 and D.3. 2. Under a microscope verify the thermocouple insulation meets the quality requirements. The insulation should be about 1/16 inch (0.062 ± 0.030) from the end of the bead (see Figure 34). Figure 34. Inspection of Insulation on Thermocouple 3. Measure the thermocouple resistance by holding both contacts on the connector on one probe and the tip of thermocouple to the other probe of the DMM (measurement should be about ~3.0 ohms for 36-gauge type T thermocouple). 4. Straighten the wire for about 38 mm [1 ½ inch] from the bead. 5. Using the microscope and tweezers, bend the tip of the thermocouple at approximately 10 degree angle by about 0.8 mm [.030 inch] from the tip (see Figure 35). 84 Thermal and Mechanical Design Guidelines