Oki ML591 Troy Etherwind 802.11b Print Server Users Guide - Page 37

DEC LAT Network Configuration, VMS LAT Host Configuration

Page 37 highlights

8 DEC LAT Network Configuration Note: Only TROY EtherWind-N models include DEC LAT support. The EtherWind wireless print server acts as a node on an Ethernet network that offers printing services to other devices. The print server comes preconfigured to run on a LAT network and does not require any additional setup. Each print server has a default node name of XCD_xxxxxx (where "xxxxxx" are the last six digits of the Ethernet address of the unit). The port name is P1 for the EIO, MIO, or first parallel port; S1 for the first serial port, P2 for the second parallel port, and S2 for the second serial port. VMS LAT Host Configuration Use the VMS editor to create a text file with the necessary configuration commands to create a LAT application port and then a VMS print queue. For example: $MCR LATCP CREATE PORT LTAxx:/APPLICATION SET PORT LTAxx:/NODE=nodename/PORT=port SHOW PORT LTAxx: EXIT $SET TERM LTAxx:/PASSTHRU/PASSALL/TAB/NOBROADCAST/PERM $SET DEVICE/SPOOL LTAxx: $INIT/QUEUE/START/ON=LTAxx:/PROC=LATSYM queuename Note: LTAxx is the available LAT port to be used nodename is the node name of the print server port is the port, e.g. P1, S1, P2, S2 & LN queuename is any unique name for the print queue. 8-1

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

DEC LAT Network
Configuration
Note:
Only TROY EtherWind-N models include DEC LAT support.
The EtherWind wireless print server acts as a node on an Ethernet network that
offers printing services to other devices.
The print server comes preconfigured to
run on a LAT network and does not require any additional setup.
Each print server has a default node name of XCD_
xxxxxx
(where "
xxxxxx
" are the
last six digits of the Ethernet address of the unit).
The port name is P1 for the
EIO, MIO, or first parallel port; S1 for the first serial port, P2 for the second par-
allel port, and S2 for the second serial port.
VMS LAT Host Configuration
Use the VMS editor to create a text file with the necessary configuration commands
to create a LAT application port and then a VMS print queue.
For example:
$MCR LATCP
CREATE PORT LTA
xx
:/APPLICATION
SET PORT LTA
xx
:/NODE=
nodename
/PORT=
port
SHOW PORT LTA
xx
:
EXIT
$SET TERM LTA
xx
:/PASSTHRU/PASSALL/-
TAB/NOBROADCAST/PERM
$SET DEVICE/SPOOL LTA
xx
:
$INIT/QUEUE/START/ON=LTA
xx
:/-
PROC=LATSYM
queuename
Note:
LTA
xx
is the available LAT port to be used
nodename
is the node name of the print server
port
is the port, e.g.
P1, S1, P2, S2 & LN
queuename
is any unique name for the print queue.
8-1
8