Tripp Lite SU1500XLCD Owner's Manual for On-Line Tower LCD UPS 933168 - Page 7

Confirm Selection, Turn Off Ups Output, Clear Ups Fault Mode

Page 7 highlights

Features CONFIRM SELECTION In the setup mode, this button can also be used to confirm the selection. 3 OFF BUTTON: : This button offers two main functions depending on the state of the UPS when it is pressed: TURN OFF UPS OUTPUT and CLEAR UPS FAULT MODES TAP the ON BUTTON during SETUP MODE operation to confirm the current selection TURN OFF UPS OUTPUT Changes UPS operating mode to STANDBY & TURNS OFF UPS OUTPUT when pressed during ONLINE, ECONOMY, BATTERY, FREQUENCY REGULATION and FREQUENCY CONVERSION MODES PRESS and HOLD the OFF BUTTON during ONLINE, ECONOMY, BATTERY, FREQUENCY REGULATION or FREQUENCY CONVERSION modes The LCD screen will advance to the next configuration item. See the Configuration section for more information HOW? TAP the ON BUTTON (less than 1 second) WHEN? The UPS must be running in SETUP MODE with the SET icon lighted for the CONFIRM SELECTION input to take effect. The UPS will immediately report OFF on the LCD screen. At this point the UPS can be unplugged and placed in storage. HOW? PRESS and HOLD the OFF BUTTON until a BEEP is heard (about 3 seconds), then RELEASE WHEN? ? The UPS must be running in ONLINE (shown above), ECONOMY, BATTERY, FREQUENCY REGULATION or FREQUENCY CONVERSION MODE for the TURN OFF UPS OUTPUT function to take effect. CLEAR UPS FAULT MODE Clears out UPS SHUTDOWN or FAULT MESSAGING on the LCD screen PRESS and HOLD the OFF BUTTON until a BEEP is heard as the UPS is reporting an ERROR CODE 13-03-138 93-3168-EN.indd 7 The error code will be reset and the UPS will return to BYPASS or STANDBY mode, depending on the FAULT encountered. HOW? PRESS and HOLD the OFF BUTTON until a BEEP is heard (about 3 seconds), then RELEASE WHEN? The UPS must be reporting an ERROR CODE (starting with "E") in order for the CLEAR UPS FAULT function to take effect 7 3/28/2013 1:04:51 PM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96

TAP the ON BUTTON during SETUP MODE operation to confirm the
current selection
The LCD screen will advance to the next configuration item.
See the Configuration section for more information
In the setup mode, this button can also be used to confirm the selection.
HOW?
TAP the ON BUTTON (less than 1 second)
WHEN?
The UPS must be running in SETUP MODE with the SET
icon lighted for the CONFIRM SELECTION input to take
effect.
7
Features
CONFIRM SELECTION
PRESS and HOLD the OFF BUTTON during ONLINE, ECONOMY,
BATTERY, FREQUENCY REGULATION or FREQUENCY CONVERSION
modes
The UPS will immediately report OFF on the LCD screen.
At this point the UPS can be unplugged and placed in storage.
3
OFF BUTTON
: : This button offers two main functions
depending on the state of the UPS when it is pressed: TURN
OFF UPS OUTPUT and CLEAR UPS FAULT MODES
HOW?
PRESS and HOLD the OFF BUTTON until a BEEP is
heard (about 3 seconds), then RELEASE
WHEN?
? The UPS must be running in ONLINE (shown above),
ECONOMY,
BATTERY,
FREQUENCY
REGULATION
or
FREQUENCY CONVERSION MODE for the TURN OFF
UPS OUTPUT function to take effect.
Changes UPS operating mode to STANDBY & TURNS OFF UPS OUTPUT
when
pressed
during
ONLINE,
ECONOMY,
BATTERY,
FREQUENCY
REGULATION and FREQUENCY CONVERSION MODES
PRESS and HOLD the OFF BUTTON
until a BEEP is heard as the
UPS is reporting an ERROR CODE
The error code will be reset and the UPS will return to BYPASS
or STANDBY mode, depending on the FAULT encountered.
HOW?
PRESS and HOLD the OFF BUTTON until a BEEP is
heard (about 3 seconds), then RELEASE
WHEN?
The UPS must be reporting an ERROR CODE (starting
with ā€œEā€) in order for the CLEAR UPS FAULT function to
take effect
Clears out UPS SHUTDOWN or FAULT MESSAGING on the LCD screen
TURN OFF UPS OUTPUT
CLEAR UPS FAULT MODE
13-03-138 93-3168-EN.indd
7
3/28/2013