iRobot Roomba 570 Service Manual - Page 72
Appendix F: Battery Test Procedure
View all iRobot Roomba 570 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 72 highlights
Appendix F: Battery Test Procedure Using Battery Voltage Tester Objective : To measure the voltage across a Roomba 500 series battery, to measure voltage across a 5-Ohm resistor, and to measure the thermistor resistance. Equipment : Battery Voltage Tester, Multimeter, and fully charged battery under test. Method 1. Fully charge battery with Roomba and latest software. Remove battery from Roomba To measure voltage across the fully charged battery, set the multimeter to measure DC VOLTAGE (V), and plug the multimeter 2. terminals to the positive (+) and negative (-) terminals of the charge barge. Failure if reading is less than 14.5V. To measure the voltage across a 5 Ω resistor, follow step 1 (set the multimeter to measure DC VOLTAGE), and press the 5-Ohm 3. resistor push button (Caution: Do not press button for more than a few seconds to avoid overheating of the load.) Failure if voltage drop is more than 2 Volts. Make sure battery is not hot from charging and needs to be equilibrated to room temperature. To measure the thermistor resistance value (thermistor contact to ground contact), set the multimeter to measure RESISTANCE (Ω), and plug the multimeter terminals to 4. the thermistor terminal and the negative (-) terminal. Failure if not within specs in table below. Ambient Room Temp 10 to 17.5 C 17.6 to 25.5 C 25.6 to 33.5 C 33.6 to 41.5 C Thermistor Min (K Ohm) 12.0 8.5 6.0 4.3 Thermistor Max (K Ohm) 21.8 15.5 11.0 7.8 72