Brother International HL-3400CN Users Manual - English - Page 175
Fusing Unit, REPLACE FUSER
UPC - 012502526223
View all Brother International HL-3400CN manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 175 highlights
USER'S GUIDE Fusing Unit Fusing Unit When the following message appears on the LCD panel, you must replace the Fusing Unit: REPLACE FUSER Warning The Fusing Unit and the parts around it are HOT!. Be sure to wait until the Fusing Unit has cooled down sufficiently before replacing the Fusing Unit. If you touch the HOT parts, you might get injured. Warning After replacing the Fusing Unit, wait for approximately 30 minutes before printing after the new unit is installed to allow the fusing oil to circulate. Replacing the Fusing Unit 1. Press the Power button to turn off the printer. Unplug the printer. To avoid injury, wait until the printer has cooled down sufficiently before replacing the Fusing Unit. 2. Open the Top Cover. 3. Unscrew the two long screws as shown to release the Fusing unit from the printer. 5-18 Fig. 5-20 Remove screws