Cisco 6513 Installation Guide - Page 30

Table 1-6, Catalyst 6504-E Switch Specifications, Chassis requires 5 RU. - weight

Page 30 highlights

Catalyst 6504-E Switch Chapter 1 Catalyst 6500 Series Switch Chassis Overview Table 1-6 Catalyst 6504-E Switch Specifications Item Environmental Temperature, operating Temperature, nonoperating and storage Thermal transition Humidity (RH), ambient (noncondensing) operating Humidity (RH), ambient (noncondensing) nonoperating and storage Altitude, operating Physical Characteristics Dimensions (H x W x D) Weight Airflow Specification Certified for operation: 32° to 104°F (0° to 40°C) Designed and tested for operation: 32° to 130°F (0° to 55°C) Note The Catalyst 6500 series switches are equipped with internal air temperature sensors that are triggered at 104°F (40°C) generating a minor alarm and at 131°F (55°C) generating a major alarm. -4° to 149°F (-20° to 65°C) 0.5°C per minute (hot to cold) 0.33°C per minute (cold to hot) 10% to 85% 5% to 95% Certified for operation: 0 to 6500 feet (0 to 2000 m) Designed and tested for operation: -200 to 10,000 feet (-60 to 3000 m) • 8.7 x 17.5 x 21.6 in. (22.09 x 44.45 x 54.86 cm). • Chassis requires 5 RU. • Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D and ETS 300-119 standards. • Chassis only: 27 lb (12.25 kg). • Chassis fully configured with 2 supervisor engines, 2 modules, and 2 AC-input power supplies: 97 lb (43.99 kg). FAN-MOD-4HS-300 CFM Note To maintain proper air circulation through the Catalyst switch chassis, we recommend that you maintain a minimum 6-inch (15 cm) separation between a wall and the chassis air intake or a wall and the chassis air exhaust. You should also allow a minimum separation of 12 inches (30.5 cm) between the hot air exhaust on one chassis and the air intake on another chassis. Failure to maintain adequate air space can cause the chassis to overheat and the system to fail. On Catalyst chassis in which the airflow is from front to back, the chassis may be placed side-by-side. 1-14 Catalyst 6500 Series Ethernet Modules Installation Guide OL-6265-03

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195
  • 196
  • 197
  • 198
  • 199
  • 200
  • 201
  • 202
  • 203
  • 204
  • 205
  • 206
  • 207
  • 208
  • 209
  • 210
  • 211
  • 212
  • 213
  • 214
  • 215
  • 216
  • 217
  • 218
  • 219
  • 220
  • 221
  • 222
  • 223
  • 224
  • 225
  • 226
  • 227
  • 228
  • 229
  • 230
  • 231
  • 232
  • 233
  • 234
  • 235
  • 236
  • 237
  • 238
  • 239
  • 240
  • 241
  • 242
  • 243
  • 244
  • 245
  • 246
  • 247
  • 248
  • 249
  • 250
  • 251
  • 252
  • 253
  • 254

1-14
Catalyst 6500 Series Ethernet Modules Installation Guide
OL-6265-03
Chapter 1
Catalyst 6500 Series Switch Chassis Overview
Catalyst 6504-E Switch
Table 1-6
Catalyst 6504-E Switch Specifications
Item
Specification
Environmental
Temperature, operating
Certified for operation: 32° to 104°F (0° to 40°C)
Designed and tested for operation: 32° to 130°F (0° to 55°C)
Note
The Catalyst 6500 series switches are equipped with internal air
temperature sensors that are triggered at 104°F (40°C) generating a
minor alarm and at 131°F (55°C) generating a major alarm.
Temperature, nonoperating
and storage
–4° to 149°F (–20° to 65°C)
Thermal transition
0.5°C per minute (hot to cold)
0.33°C per minute (cold to hot)
Humidity (RH), ambient
(noncondensing) operating
10% to 85%
Humidity (RH), ambient
(noncondensing)
nonoperating and storage
5% to 95%
Altitude, operating
Certified for operation: 0 to 6500 feet (0 to 2000 m)
Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m)
Physical Characteristics
Dimensions (H x W x D)
8.7 x 17.5 x 21.6 in. (22.09 x 44.45 x 54.86 cm).
Chassis requires 5 RU.
Chassis can be mounted in equipment racks that meet ANSI/EIA 310-D
and ETS 300-119 standards.
Weight
Chassis only: 27 lb (12.25 kg).
Chassis fully configured with 2 supervisor engines, 2 modules, and
2 AC-input power supplies: 97 lb (43.99 kg).
Airflow
FAN-MOD-4HS—300 CFM
Note
To maintain proper air circulation through the Catalyst switch
chassis, we recommend that you maintain a minimum 6-inch (15 cm)
separation between a wall and the chassis air intake or a wall and the
chassis air exhaust. You should also allow a minimum separation of
12 inches (30.5 cm) between the hot air exhaust on one chassis and
the air intake on another chassis. Failure to maintain adequate air
space can cause the chassis to overheat and the system to fail. On
Catalyst chassis in which the airflow is from front to back, the
chassis may be placed side-by-side.