Dell External OEMR 1435 User Guide - Page 109

Table A-1., BMC Management Utility Error Codes, Classification, Message, Description, Error

Page 109 highlights

Table A-1. BMC Management Utility Error Codes (continued) Code A8h A9h Classification Message Description IPMI Error First index larger than The first index is larger total SEL records. than the total SEL records. H/W or F/W Unsupported errors. command. Unsupported operation. 0xC1 Sensor not present. Request sensor, data, or 0xCB record not present. Sensor command error. Command illegal for specified sensor or record type. 0xCD Firmware error. Command response 0xCE could not be provided. Destination error. Cannot deliver request 0xD3 to destination. Device error. Device specific (OEM) 0x01-0x errors. 7E Processing BMC busy. errors (transient errors that may disappear upon retry of command). BMC out of processing 0xC0 resources. Destination timeout BMC timeout while 0xC3 error. processing command BMC out of storage space. BMC out of storage space required to process command. 0xC4 Invalid reservation ID. Invalid reservation ID. 0xC5 Duplicate command. Cannot execute duplicated request. 0xCF BMC Management Utility Error Codes 109

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156

BMC Management Utility Error Codes
109
First index larger than
total SEL records.
The first index is larger
than the total SEL
records.
A8h
H/W or F/W
errors.
Unsupported
command.
Unsupported
operation.
0xC1
Sensor not present.
Request sensor, data, or
record not present.
0xCB
Sensor command
error.
Command illegal for
specified sensor or
record type.
0xCD
Firmware error.
Command response
could not be provided.
0xCE
Destination error.
Cannot deliver request
to destination.
0xD3
Device error.
Device specific (OEM)
errors.
0x01–0x
7E
A9h
Processing
errors
(transient
errors that
may disappear
upon retry of
command).
BMC busy.
BMC out of processing
resources.
0xC0
Destination timeout
error.
BMC timeout while
processing command
0xC3
BMC out of storage
space.
BMC out of storage
space required to
process command.
0xC4
Invalid reservation ID.
Invalid reservation ID.
0xC5
Duplicate command.
Cannot execute
duplicated request.
0xCF
Table A-1.
BMC Management Utility Error Codes
(continued)
Code
Classification
Message
Description
IPMI
Error