Dell PowerEdge R310 Hardware Owner's Manual - Page 26
Table 1-2., LCD Status Messages Optional, Causes, Corrective Actions, E1211 RAID - voltage
View all Dell PowerEdge R310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 26 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code Text Causes Corrective Actions E1114 Ambient Temp Ambient temperature has See "Troubleshooting exceeds reached a point outside of System Cooling allowed range. the allowed range. Problems" on page 151. E1116 Memory Memory has exceeded Remove AC power to the disabled, temp allowable temperature and system for 10 seconds and above range. has been disabled to restart the system. Power cycle AC. prevent damage to the components. See "Troubleshooting System Cooling Problems" on page 151. If the problem persists, see "Getting Help" on page 169. E1210 Motherboard CMOS battery is missing See "Troubleshooting the battery or the voltage is outside of System Battery" on failure. Check the allowable range. page 150. battery. E1211 RAID RAID battery is either Reseat the RAID battery Controller missing, bad, or unable to connector. See battery recharge due to thermal "Troubleshooting System failure. Check issues. Cooling Problems" on battery. page 151. E1216 3.3V Regulator 3.3 V voltage regulator has Remove and reseat the failure. failed. PCIe expansion cards. Reseat PCIe If the problem persists, cards. see "Troubleshooting an Expansion Card" on page 159. E1229 CPU # VCORE Regulator failure. Reseat CPU. Specified processor Reseat the processor. See VCORE voltage regulator "Troubleshooting the has failed. Processor" on page 160. If the problem persists, see "Getting Help" on page 169. 26 About Your System