Dell PowerEdge R310 Hardware Owner's Manual - Page 39
Check PSU and, Alert! System - wattage
View all Dell PowerEdge R310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
Table 1-3. System Messages (continued) Message Causes Corrective Actions Alert! iDRAC6 not The optional iDRAC6 responding. has hung. Power required may exceed PSU wattage. The optional iDRAC6 was remotely reset while system was booting. Alert! Continuing system boot accepts the risk After AC recovery, the optional iDRAC6 takes longer than normal to boot. that system may power down without warning. Remove AC power to the system for 10 seconds and restart the system. Alert! Power required exceeds PSU wattage. Check PSU and system configuration. The system configuration of processor, memory modules, and expansion cards may not be supported by the power supplies. Alert! Continuing system boot accepts the risk that system may power down without warning. If any system components were just upgraded, return the system to the previous configuration. If the system boots without this warning, then the replaced component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with High Output power supplies to use the components. See "Power Supplies" on page 125. Alert! System fatal error during previous boot. An error caused the system to Check other system reboot. messages for additional information for possible causes. About Your System 39