Dell PowerEdge R310 Hardware Owner's Manual - Page 32
SAS cable - review
View all Dell PowerEdge R310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code Text Causes Corrective Actions E1810 Hard drive ## The specified hard drive fault. Review has experienced a fault. & clear SEL. See "Troubleshooting a Hard Drive" on page 158. E1812 Hard drive ## The specified hard removed. Check drive has been removed drive. from the system. Information only. E1920 iDRAC6 Upgrade optional iDRAC6 Failed. upgrade has failed. See "Getting Help" on page 169. E1A14 SAS cable A SAS cable A is missing failure. Check or bad. connection. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 169. E1A15 SAS cable B SAS cable B is missing failure. Check or bad. connection. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 169. E1A1D Control panel USB cable not detected. Check cable. USB cable to the control panel is missing or bad. Reseat the cable. If the problem persists, replace cable. If the problem persists, see "Getting Help" on page 169. E2010 Memory not No memory was detected detected. in the system. Inspect DIMMs. Install memory or reseat memory modules. See "Troubleshooting System Memory" on page 153. E2011 Memory configuration failure. Check DIMMs. Memory detected, but is not configurable. Error detected during memory configuration. See "Troubleshooting System Memory" on page 153. 32 About Your System