Dell PowerEdge R310 Hardware Owner's Manual - Page 27
E122D Memory, E122E On-board
View all Dell PowerEdge R310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code E122A E122C E122D E122E E1310 E1311 E1313 Text CPU # VTT Regulator failure. Reseat CPU. Causes Specified processor VTT voltage regulator has failed. CPU Power Fault. Power cycle AC. A power fault was detected when powering up the processor. Memory Regulator # One of the memory regulators has failed. Failed. Reseat DIMMs. On-board regulator failed. Call support. One of the on-board voltage regulators failed. Fan ## RPM exceeding range. Check fan. RPM of specified fan is outside of the intended operating range. Fan module ## RPM exceeding range. Check fan. RPM of specified fan in specified module is outside of intended operating range. Fan redundancy The system is no longer lost. Check fan redundant. Another fans. fan failure would put the system at risk of over-heating. Corrective Actions Reseat the processor. See "Troubleshooting the Processor" on page 160. If the problem persists, see "Getting Help" on page 169. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. Reseat the memory modules. See "Troubleshooting System Memory" on page 153. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. See "Troubleshooting System Cooling Problems" on page 151. See "Troubleshooting System Cooling Problems" on page 151. Check LCD for additional scrolling messages. See "Troubleshooting a Fan" on page 152. About Your System 27