Check PSU., Install two High Output or
View all Dell PowerEdge R310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 50 highlights
Table 1-3. System Messages (continued) Message Causes Corrective Actions Warning! Power The system configuration of If any system components required exceeds processor, memory modules, were just upgraded, return PSU wattage. and expansion cards may not the system to the previous Check PSU and be supported by the power configuration. If the system system supplies. boots without this warning, configuration. then the replaced Warning! Performance degraded. CPU and memory set to minimum frequencies to meet PSU wattage. System will reboot. component(s) are not supported with this power supply. If Energy Smart power supplies are installed, replace them with the High Output power supplies to use the components. See "Power Supplies" on page 125. Warning! PSU mismatch. PSU redundancy lost. Check PSU. A High Output power supply Install two High Output or and an Energy Smart power two Energy Smart power supply are installed in the supplies in the system. system at the same time. You can also run the system on one power supply until you can obtain two power supplies of the same type. See "Troubleshooting Power Supply" on page 151. Warning! Unsupported memory configuration detected. The memory configuration is not optimal. The recommended memory configuration is: . Invalid memory configuration. The system will run but with reduced functionality. Ensure that the memory modules are installed in a valid configuration. See "General Memory Module Installation Guidelines" on page 106. If the problem persists, see "Troubleshooting System Memory" on page 153. 50 About Your System