Dell PowerEdge R310 Hardware Owner's Manual - Page 36
LCD Log Full., Check SEL - memory upgrade
View all Dell PowerEdge R310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 36 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code Text Causes Corrective Actions E2111 SBE log disabled on DIMM ##. Reseat DIMM. The system BIOS has disabled memory single-bit error (SBE) logging and will not log anymore SBEs until the system is rebooted. "##" represents the memory module implicated by the BIOS. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Troubleshooting System Memory" on page 153. I1910 Intrusion detected. Check chassis cover. System cover has been removed. Information only. I1911 LCD Log Full. Check SEL to review all Errors. LCD overflow message. Check the SEL for details A maximum of ten error on the events. messages can display Remove AC power to the sequentially on the LCD. system for 10 seconds or The eleventh message clear the SEL. instructs the user to check the SEL for details on the events. I1912 SEL full. The SEL is full of events Check the SEL for details Review & clear and is unable to log any on the events, then clear log. more. the SEL. I1920 iDRAC6 Upgrade optional iDRAC6 has Successful. been upgraded successfully. Information only. W1228 RAID Controller battery capacity < 24hr. Warns predictively that the RAID battery has less than 24 hours of charge left. Allow RAID battery to charge to greater than 24 hours of sustained charge. If problem persists, replace RAID battery. See "Getting Help" on page 169. 36 About Your System