Dell PowerEdge R310 Hardware Owner's Manual - Page 33
E2016 Interrupt, Check DIMMs. - ram
View all Dell PowerEdge R310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 33 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code Text Causes Corrective Actions E2012 Memory Memory configured, but is See "Troubleshooting configured but unusable. System Memory" on unusable. page 153. Check DIMMs. E2013 BIOS unable to The system BIOS failed to See "Troubleshooting shadow memory. copy its flash image into System Memory" on Check DIMMs. memory. page 153. E2014 CMOS RAM CMOS failure. CMOS failure. Power RAM not functioning cycle AC. properly. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. E2015 DMA Controller DMA controller failure. failure. Power cycle AC. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. E2016 Interrupt Controller Interrupt controller failure. failure. Power cycle AC. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. E2017 Timer refresh Timer refresh failure. failure. Power cycle AC. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. About Your System 33