Dell PowerEdge R310 Hardware Owner's Manual - Page 29
CPU Bus parity, E1618 Predictive - error 1
View all Dell PowerEdge R310 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 29 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code Text Causes Corrective Actions E1420 CPU Bus parity The system BIOS has error. Power reported a processor bus cycle AC. parity error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. E1422 CPU # machine check error. Power cycle AC. The system BIOS has reported a machine check error. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. E1610 Power Supply # (### W) missing. Check power supply. Specified power supply was removed or is missing from the system. See "Troubleshooting Power Supply" on page 151. E1614 Power Supply # Specified power supply (### W) error. has failed. Check power supply. See "Troubleshooting Power Supply" on page 151. E1618 Predictive failure on Power Supply # (### W). Check PSU. An over-temperature condition or power supply communication error has caused the predictive warning of an impending power supply failure. See "Troubleshooting Power Supply" on page 151. E161C Power Supply # Specified power supply is (### W) lost attached to the system, AC power. Check PSU but it has lost its AC input. cables. Check the AC power source for the specified power supply. If the problem persists, see "Troubleshooting Power Supply" on page 151. About Your System 29