Page 30 highlights
Table 1-2. LCD Status Messages (Optional) (continued) Code Text Causes Corrective Actions E1620 Power Supply # (### W) AC power error. Check PSU cables. Specified power supply's Check the AC power AC input is outside of the source for the specified allowable range. power supply. If the problem persists, see "Troubleshooting Power Supply" on page 151. E1624 Lost power supply redundancy. Check PSU cables. The power supply subsystem is no longer redundant. If the remaining power supply fails, the system will shut down. See "Troubleshooting Power Supply" on page 151. E1626 Power Supply The power supplies in Mismatch. PSU1 the system are not the = ### W, PSU2 same wattage. = ### W. Ensure that power supplies with matching wattage are installed. See the Technical Specifications outlined in your system's Getting Started Guide. E1629 Power required > PSU wattage. Check PSU and config. The system configuration requires more power than the power supplies can provide, even with throttling. Turn off power to the system, reduce the hardware configuration or install higher-wattage power supplies, and then restart the system. E1710 I/O channel check error. Review & clear SEL. The system BIOS has reported an I/O channel check. Check the SEL for more information and then clear the SEL. Remove AC power to the system for 10 seconds and restart the system. If the problem persists, see "Getting Help" on page 169. 30 About Your System
![](/manual_guide/products/dell-poweredge-r310-hardware-owners-manual-5401b8f/30.png)