Error Code FAN0000 FAN0001 FAN1201 HWC1001 HWC2003 HWC2005 Message Information 5. If the issue persists, see Getting Help. Message Details Action Message LCD Message Details Action Message LCD Message Details Action Message LCD Message Details Action Message LCD Message Details Action Message LCD Message Details Fan RPM is less than the lower warning threshold. Fan operating speed is out of range. Remove and reinstall the fan. If the issue persists, see Getting Help. Fan RPM is less than the lower critical threshold. Fan RPM is outside of range. Check fan. Fan operating speed is out of range. Remove and reinstall the fan. If the issue persists, see Getting Help. Fan redundancy is lost. Fan redundancy is lost. Check fans. Fan has failed. Remove and reinstall failed fans or install additional fans. The is absent. The is absent. Check hardware. The absent device may be necessary for proper operation. System functionality may be degraded. Reinstall or reconnect the hardware. The storage cable is not connected, or is improperly connected. Storage cable or interconnect failure. Check connection. The cable may be necessary for proper operation. System functionality may be degraded. Check if the cable is present, then reinstall or reconnect. The system board cable is not connected, or is improperly connected. System board cable connection failure. Check connection. The cable may be necessary for proper operation. System functionality may be degraded. 144