Dell PowerVault 56F Dell PowerVault 56F 16-Port Fibre Channel Switch Inst - Page 83
psShow, er_disc_c3, transfer, opened, starve_stop, fl_tenancy, nl_tenancy, frame_nozone
View all Dell PowerVault 56F manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 83 highlights
er_disc_c3 open transfer opened starve_stop fl_tenancy nl_tenancy frame_nozone Receive link: the number of Class 3 frames discarded.; class 3 frames can be discarded due to timeouts or invalid/unreachable destinations; this quantity could increment at times during normal operation but might be used for diagnosing problems in some situations. loop_open: the number of times FL_Port entered the OPEN state. loop_transfer: the number of times FL_Port entered the TRANSFER state. FL_Port opened: the number of times FL_Port entered the OPENED state. Loop tenancies stopped due to starvation Number of times FL_Port has the loop tenancy Number of times NL_Port has the loop tenancy Number of frames rejected due to zone protection The following example shows the psShow command screen, which displays the power supply status and manufacture information. The format of the display varies according to the switch model and number of power supplies present. The status of each supply is shown in Table 4-16. support.dell.com OK Absent Faulty Power supply present and functioning correctly Power supply not present Power supply is present but faulty (no power cable, power switch turned off, fuse blown, or other internal error) After the status line, a power supply identification line may be shown. If present, this line contains manufacture date, part numbers, serial numbers, and other information. PowerVault 56F 16-Port Fibre Channel Switch Commands 4-27