Dell PowerVault MD3000i Command Line Interface Guide - Page 159
Reset Storage Array SAS PHY Baseline, Reset Storage Array Virtual Disk Distribution
View all Dell PowerVault MD3000i manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 159 highlights
Parameters None. NOTE: This command resets the baseline to 0 for both RAID controller modules in the storage array. The purpose of resetting both of the RAID controller module baselines is to help ensure that the counts are synchronized between the RAID controller modules. If one RAID controller module resets but the second RAID controller module does not reset, the host is informed that the RAID controller modules are out of synchronization. The host is informed by the time stamps that are reported with the statistics. Example -c "reset storageArray iscsiStatsBaseline;" Reset Storage Array SAS PHY Baseline This command resets the SAS PHY baseline for all SAS devices in a storage array. Syntax reset storageArray SASPHYBaseline Parameters None. Example -c "delete host [\"job2900\"];" Reset Storage Array Virtual Disk Distribution This command reassigns (moves) all virtual disks to their preferred RAID controller module. Syntax reset storageArray virtualDiskDistribution Parameters None. Script Commands 159