Example 1, Position: Middle, Selected range = Enable, Start = 50 mm, End = 200 mm
UPC - 097564307270
View all Fujitsu 6240 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 183 highlights
Chapter 9 Operational Settings z When both [Start] and [End] are set to "0", multifeed detection is performed for the whole area regardless of whether it is enabled or disabled. z To disable multifeed detection for the whole document, select [Disable] and set the start position to "0" and the end position to equal the document length or longer. z If you set a value larger than the document length for the start position, selecting [Disable] detects the whole length of the document and selecting [Enable] disables the multifeed detection. z To detect multifeeds, the detection range must be at least 5 mm in length. Configure the setting so that the value of the end position minus the start position is 6 mm or more. z You can also set the start and the end positions by the following methods: - Draw an area with the mouse on the displayed image. - Drag the handles for [Start] and [End] positions on the displayed image. Feed direction Example 1: Position: Middle Selected range = Enable, Start = 50 mm, End = 200 mm 35 50 200 Unit: mm Multifeeds are detected for the area in light blue. TOP Contents Index Introduction Scanner Overview How to Load Documents Configuring the Scan Settings How to Use the Operator Panel Various Ways to Scan Daily Care Replacing the Consumables Troubleshooting Operational Settings Appendix Glossary 183