Fujitsu MPD3173AT Product Manual - Page 118

Attribute ID

Page 118 highlights

The attribute value information is 512-byte data; the format of this data is shown below. The host can access this data using the SMART Read Attribute Values subcommand (FR register = D0h). The insurance failure threshold value data is 512-byte data; the format of this data is shown below. The host can access this data using the SMART Read Attribute Thresholds subcommand (FR register = D1h). Table 5.9 Format of device attribute value data Byte Item 00 Data format version number 01 02 Attribute 1 Attribute ID 03 Status flag 04 05 Current attribute value 06 Attribute value for worst case so far 07 Raw attribute value to 0C 0D Reserved 0E Attribute 2 to (The format of each attribute value is the same as to attribute 30 that of bytes 02 to 0D.) 169 16A Reserved to 16F 170 Failure prediction capability flag 171 172 Reserved to 181 182 Vendor specific to 1FE 1FF Check sum C141-E069-02EN 5 - 51

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191

C141-E069-02EN
5 - 51
The attribute value information is 512-byte data; the format of this data is shown below.
The
host can access this data using the SMART Read Attribute Values subcommand (FR register =
D0h).
The insurance failure threshold value data is 512-byte data; the format of this data is
shown below.
The host can access this data using the SMART Read Attribute Thresholds
subcommand (FR register = D1h).
Table 5.9
Format of device attribute value data
Byte
Item
00
01
Data format version number
02
Attribute 1
Attribute ID
03
04
Status flag
05
Current attribute value
06
Attribute value for worst case so far
07
to
0C
Raw attribute value
0D
Reserved
0E
to
169
Attribute 2 to
attribute 30
(The format of each attribute value is the same as
that of bytes 02 to 0D.)
16A
to
16F
Reserved
170
171
Failure prediction capability flag
172
to
181
Reserved
182
to
1FE
Vendor specific
1FF
Check sum