Table 5.5, Information to be read by IDENTIFY DEVICE command 1 of 4
View all Fujitsu MPD3173AT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 97 highlights
Table 5.5 Information to be read by IDENTIFY DEVICE command (1 of 4) Word 0 1 2 3 4 5 6 7-9 10-19 20 21 22 23-26 27-46 47 48 49 50 51 52 53 54 55 56 57-58 59 60-61 62 63 64 65 66 67 68 69-79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94-127 128 129-255 Value X'045A' *2 X'0000' *3 X'0000' X'0000' X'003F' X'000000000000' - X'0000' X'0400' X'0004' - - X'8010' X'0000' X'0B00' X'0000' X'0200' X'0000' X'0007' (Variable) (Variable) (Variable) (Variable) *10 *11 X'0000' X'xx07' X'0003' X'0078' X'0078' X'0078' X'0078' X'00' X'001E' X'0000' X'346B' X'4008' X'4000' X'00xx' X'000x' X'4000' X'xx1F' X'0000' X'0000' X'00xx' X'0000' X'x000' X'00' X'xx' X'00' Description General Configuration *1 Number of cylinders Reserved Number of Heads Retired Retired Number of sectors per track Retired Serial number (ASCII code) *4 Retired Buffer size in 512 byte increments Number of ECC bytes transferred at READ LONG or WRITE LONG command Firmware revision (ASCII code) *5 Model number (ASCII code) *6 Maximum number of sectors per interrupt on READ/WRITE MULTIPLE command Reserved Capabilities *7 Reserved PIO data transfer mode *8 Retired Enable/disable setting of words 54-58, 64-70 and 88 *9 Number of current Cylinders Number of current Head Number of current sectors per track Total number of current sectors Transfer sector count currently set by READ/WRITE MULTIPLE command Total number of user addressable sectors (LBA mode only) Retired Multiword DMA transfer mode *12 Advance PIO transfer mode support status *13 Minimum multiword DMA transfer cycle time per word : 120 [ns] Manufacturer's recommended DMA transfer cycle time : 120 [ns] Minimum PIO transfer cycle time without flow control : 120 [ns] Minimum PIO transfer cycle time with IORDY flow control : 120 [ns] Reserved Major version number *14 Minor version number (not reported) Support of command sets *15 Support of command sets *16 Support of command set/feature extension (fixed) Enable/disable Command set/feature enabled. *17 Enable/disable Command set/feature enabled. *18 Default of command set/feature (fixed) Ultra DMA modes *19 Time required for security erase unit completion Time required for Enhanced security erase completion Current advanced power management value Reserved CBLID detection results *20 Reserved Security Status Reserved 5 - 30 C141-E069-02EN