Fujitsu MPD3173AT Product Manual - Page 136
Security Set Password
View all Fujitsu MPD3173AT manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 136 highlights
Note: For transfer of a sector of data, the host needs to read Status register (X'1F7') in order to clear INTRQ (interrupt) signal. The Status register should be read within a period from the DRQ setting by the device to 5 µs after the completion of the sector data transfer. Note that the host does not need to read the Status register for the reading of a single sector or the last sector in multiple-sector reading. If the timing to read the Status register does not meet above condition, normal data transfer operation is not guaranteed. When the host new command even if the device requests the data transfer (setting in DRQ bit), the correct device operation is not guaranteed. Command Parameter write ~ BSY DRDY Status read DRQ INTRQ Data transfer * Transfers dummy data * The host should receive 512-byte dummy data or release the DRQ set state by resetting. Figure 5.3 Protocol for command abort 5.4.2 Data transferring commands from host to device The execution of the following commands involves Data transfer from the host to the drive. • FORMAT TRACK • WRITE SECTOR(S) • WRITE LONG • WRITE BUFFER • WRITE VERIFY • SECURITY DISABLE PASSWORD • SECURITY ERASE UNIT • SECURITY SET PASSWORD • SECURITY UNLOCK The execution of these commands includes the transfer one or more sectors of data from the host to the device. In the WRITE LONG command, 516 bytes are transferred. Following shows the protocol outline. C141-E069-02EN 5 - 69