HP 6125XLG R2306-HP 6125XLG Blade Switch High Availability Command Reference - Page 113
bfd multi-hop min-receive-interval
View all HP 6125XLG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 113 highlights
Default The multi-hop detection time multiplier is 5. Views System view Predefined user roles network-admin Parameters value: Specifies the multi-hop detection time multiplier in the range of 3 to 50. Usage guidelines The detection time multiplier determines the maximum number of concurrent BFD control packets that can be discarded. Table 31 Detection interval calculation method Mode Detection interval Control packet mode BFD session in Detection time multiplier of the receiver × actual asynchronous mode packet sending interval of the receiver Control packet mode BFD session in demand Detection time multiplier of the sender × actual mode packet sending interval of the sender Examples # Configure the multi-hop detection time multiplier as 6. system-view [Sysname] bfd multi-hop detect-multiplier 6 bfd multi-hop min-receive-interval Use bfd multi-hop min-receive-interval to configure the minimum interval for receiving multi-hop BFD control packets. Use undo bfd multi-hop min-receive-interval to restore the default. Syntax bfd multi-hop min-receive-interval value undo bfd multi-hop min-receive-interval Default The minimum interval for receiving multi-hop BFD control packets is 400 milliseconds. Views System view Predefined user roles network-admin 108