HP 6125XLG R2306-HP 6125XLG Blade Switch High Availability Command Reference - Page 37
cfd enable
View all HP 6125XLG manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 37 highlights
Syntax cfd cc interval interval-value service-instance instance-id undo cfd cc interval [ interval-value ] service-instance instance-id Default The value of this field is 4 for all CCMs sent. Views System view Predefined user roles network-admin Parameters interval interval-value: Specifies the value of the interval field in CCM messages. The value range for the interval field is 1 to 7. This Switch Series does not support an interval field value in the range of 1 to 3. If you configure the interval field value as 1, 2, or 3, the value 4 takes effect. service-instance instance-id: Specifies the service instance ID in the range of 1 to 32767. Usage guidelines When setting the CCM interval, use the settings described in Table 6. Table 6 CCM interval field encoding CCM interval field 1 2 3 4 5 6 7 Transmission interval 10/3 milliseconds 10 milliseconds 100 milliseconds 1 second 10 seconds 60 seconds 600 seconds Maximum CCM lifetime 35/3 milliseconds 35 milliseconds 350 milliseconds 3.5 seconds 35 seconds 210 seconds 2100 seconds Examples # Set the value of the interval field in CCMs sent by MEPs in service instance 2 to 7. system-view [Sysname] cfd cc interval 7 service-instance 2 Related commands cfd cc enable cfd enable Use cfd enable to enable CFD. Use undo cfd enable to disable CFD. Syntax cfd enable 32