HP 6125XLG R2306-HP 6125XLG Blade Switch High Availability Command Reference - Page 13

Usage guidelines, Examples

Page 13 highlights

Usage guidelines If you do not specify the interface keyword, this command displays the statistics on the Ethernet OAM link error events occurred on all the local/peer ports. Examples # Display the statistics on Ethernet OAM link error events occurred on all the local ports. display oam link-event local Ten-GigabitEthernet1/1/5 Link status: UP OAM local errored frame event Event time stamp : 49582 x 100 milliseconds Errored frame window : 10 x 100 milliseconds Errored frame threshold : 1 error frames Errored frame : 1 error frames Error running total : 6 error frames Event running total : 6 events OAM local errored frame period event Event time stamp : 16382 x 100 milliseconds Errored frame period window : 10000000 frames Errored frame period threshold : 1 error frames Errored frame period : 1 error frames Error running total : 5 error frames Event running total : 5 events OAM local errored frame seconds summary event Event time stamp : 50022 x 100 milliseconds Errored frame seconds window : 600 x 100 milliseconds Errored frame seconds threshold : 1 error seconds Errored frame seconds : 1 error seconds Error running total : 1 error seconds Event running total : 1 events # Display Ethernet OAM link event statistics of the remote ends of all the ports. display oam link-event remote Ten-GigabitEthernet1/1/5 Link status: UP OAM remote errored symbol event Event time stamp : 35498 x 100 milliseconds Errored symbol window : 100000000 symbols Errored symbol threshold : 1 error symbols Errored symbol : 1 error symbols Error running total : 4 error symbols Event running total : 4 events OAM remote errored frame event Event time stamp : 49582 x 100 milliseconds Errored frame window : 10 x 100 milliseconds Errored frame threshold : 1 error frames Errored frame : 1 error frames Error running total : 6 error frames Event running total : 6 events 8

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

8
Usage guidelines
If you do not specify the
interface
keyword, this command displays the statistics on the Ethernet OAM link
error events occurred on all the local/peer ports.
Examples
# Display the statistics on Ethernet OAM link error events occurred on all the local ports.
<Sysname> display oam link-event local
----------- [Ten-GigabitEthernet1/1/5] -----------
Link status: UP
OAM local errored frame event
Event time stamp
: 49582 x 100 milliseconds
Errored frame window
: 10 x 100 milliseconds
Errored frame threshold : 1 error frames
Errored frame
: 1 error frames
Error running total
: 6 error frames
Event running total
: 6 events
OAM local errored frame period event
Event time stamp
: 16382 x 100 milliseconds
Errored frame period window
: 10000000 frames
Errored frame period threshold : 1 error frames
Errored frame period
: 1 error frames
Error running total
: 5 error frames
Event running total
: 5 events
OAM local errored frame seconds summary event
Event time stamp
: 50022 x 100 milliseconds
Errored frame seconds window
: 600 x 100 milliseconds
Errored frame seconds threshold : 1 error seconds
Errored frame seconds
: 1 error seconds
Error running total
: 1 error seconds
Event running total
: 1 events
# Display Ethernet OAM link event statistics of the remote ends of all the ports.
<Sysname> display oam link-event remote
----------- [Ten-GigabitEthernet1/1/5] -----------
Link status: UP
OAM remote errored symbol event
Event time stamp
: 35498 x 100 milliseconds
Errored symbol window
: 100000000
symbols
Errored symbol threshold : 1 error symbols
Errored symbol
: 1 error symbols
Error running total
: 4 error symbols
Event running total
: 4 events
OAM remote errored frame event
Event time stamp
: 49582 x 100 milliseconds
Errored frame window
: 10 x 100 milliseconds
Errored frame threshold : 1 error frames
Errored frame
: 1 error frames
Error running total
: 6 error frames
Event running total
: 6 events