HP 6125XLG R2306-HP 6125XLG Blade Switch High Availability Command Reference - Page 24

oam global errored-frame-period window, oam global errored-frame-seconds threshold, Related commands

Page 24 highlights

[Sysname] oam global errored-frame-period threshold 100 Related commands • display oam configuration • display oam link-event • oam errored-frame-period threshold oam global errored-frame-period window Use oam global errored-frame-period window to set the global errored frame period event detection window. Use undo oam global errored-frame-period window to restore the default. Syntax oam global errored-frame-period window window-value undo oam global errored-frame-period window Default The global errored frame period event detection window is 10000000. Views System view Predefined user roles network-admin Parameters window-value: Specifies the errored frame period event detection window in the range of 1 to 65535. The value of this argument must be a multiple of 10000. Usage guidelines The configuration in system view takes effect on all ports, but has a lower precedence than the configuration in interface view. Examples # Set the errored frame period event detection window to 20000000. system-view [Sysname] oam global errored-frame-period window 2000 Related commands • display oam configuration • display oam link-event • oam errored-frame-period window oam global errored-frame-seconds threshold Use oam global errored-frame-seconds threshold to set the global errored frame seconds event triggering threshold. Use undo oam global errored-frame-seconds threshold to restore the default. 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130

19
[Sysname] oam global errored-frame-period threshold 100
Related commands
display oam
configuration
display oam link-event
oam errored-frame-period threshold
oam global errored-frame-period window
Use
oam global errored-frame-period window
to set the global errored frame period event detection
window.
Use
undo oam global errored-frame-period window
to restore the default.
Syntax
oam global errored-frame-period window
window-value
undo oam global errored-frame-period window
Default
The global errored frame period event detection window is 10000000.
Views
System view
Predefined user roles
network-admin
Parameters
window-value
: Specifies the errored frame period event detection window in the range of 1 to 65535.
The value of this argument must be a multiple of 10000.
Usage guidelines
The configuration in system view takes effect on all ports, but has a lower precedence than the
configuration in interface view.
Examples
# Set the errored frame period event detection window to 20000000.
<Sysname> system-view
[Sysname] oam global errored-frame-period window 2000
Related commands
display oam configuration
display oam link-event
oam errored-frame-period window
oam global errored-frame-seconds threshold
Use
oam global errored-frame-seconds threshold
to set the global errored frame seconds event
triggering threshold.
Use
undo oam global errored-frame-seconds threshold
to restore the default.